Using The Inverter - Dometic SINEPOWER DSP1312T Installation And Operating Manual

Energy & lighting sinepower
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
SinePower
10

Using the inverter

10.1
Switching on the inverter
➤ Set the main switch (fig. 2 1) of the inverter as follows:
– "0": to switch the inverter permanently off
– "I": to switch the inverter permanently on
– "II": to switch the inverter on and off with a remote control (accessory)
➤ The inverter performs a self-test when starting.
✓ After the self-test is completed successfully, the LED lights up blue (fig. 2 2).
10.2
Status indications
The blue LED (fig. 2 2) shows the operating condition of the inverter.
Display
Constantly lit
Long flash, short interruption
Quick flash
Short flash, long interruption
Off
The inverter switches off if:
• The battery voltage drops below 10 V (12 Vg connection) or
20 V (24 Vg connection).
• The battery voltage exceeds 16.5 V (12 Vg connection) or
33 V (24 Vg connection).
• The inverter is overloaded.
• The inverter overheats.
➤ If this happens, shut down the inverter with the main switch (fig. 2 1).
➤ Check that the inverter is sufficiently ventilated and that the ventilation grilles are
unimpeded.
➤ Wait 5 – 10 minutes and switch the inverter on again without any electric
consumers.
EN
Input voltage
Normal mode
Inverter overheated/Overload
Overvoltage/Undervoltage
Insulation monitor has shut down the inverter
Other fault
Using the inverter
17