Domestic Hot Water Mode; Frost Protection Mode; Pump Protection; Gas Piping - Baxi LUNA HT 1.450 Installation And Servicing Instructions

Condensing gas fired wall hung boiler
Table of Contents

Advertisement

Available languages

Available languages

3.8 DOMESTIC HOT WATER MODE

A Domestic Hot Water mode is available only with an external water tank (see Section 11.2).
DANGER
Water temperature over 125 °F (51 °C) can cause severe burns instantly, or death from scalds. Children, disabled,
and elderly are at highest risk of being scalded. See user's instructions before setting the water temperature.
1. Priority is given to the domestic hot water supply. A demand at a tap or shower will override any central heating requi-
rement.
2. The combustion fan will then come on and begin to run at ignition speed.
3. Once the fan reaches ignition speed the control board will allow power to flow to the spark generator and gas valve
creating ignition in the combustion chamber. The flame sensor will acknowledge the presence of the flame. In the
combustion chamber and send a signal to the control board.
4. The temperature sensors will send a signal to the control board allowing the control board to increase/ decrease the
speed of the fan. The combustion fan will in turn modulate the gas rate accordingly.
5. When the domestic hot water demand ceases the burner will extinguish, unless there is a demand for central heating.
The frost protection mode is integrated into the appliance when left in the domestic hot water or central heating posi-
tion. If the temperature falls below 41 °F / 5° C the boiler will fire on its minimum setting until a flow temperature of 86 °F
/ 30 °C is reached.
With the selector switch in either, the central heating or domestic hot water position, the pump will automatically oper-
ate for 1 minute in every 24 hours to prevent ceasing.
Run the gas supply line in accordance with all applicable codes.
Locate and install manual shutoff valve before the gas valve as shown in figure 2 (D) - section 3, in accordance with
state and local requirements.
WARNING
A sediment trap must be provided upstream of the gas controls.
INSTALLATION AND SERVICING INSTRUCTIONS

3.9 FROST PROTECTION MODE

3.10 PUMP PROTECTION

3.11 GAS PIPING

15
(WITH EXTERNAL WATER TANK)
7110242.02 - en

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Luna ht 1.650

Table of Contents