Aiphone IX Series Owners & Installation Manual page 16

Networked video intercom system
Hide thumbs Also See for IX Series:
Table of Contents

Advertisement

*1 Contact Input Specifications
Input method
Detection time
Contact resistance
Terminal short-circuit current
Voltage between terminals
*2 Audio Output Specifications
Output impedance
Output audio level
*3 Relay Output Specifications
Output method
Contact rating
*4 The intercom unit can be powered by using a PoE switch or Aiphone PS-2420 power supply. In the case "PoE
PSE" output of the intercom unit is used to power other devices, IEEE802.3at compatible PoE switch must be used to
power the intercom unit.
In the case both a PoE switch and Aiphone PS-2420 power supply are used in combination to power the intercom
unit,PS-2420 can provide back-up power if the PoE power supply fails. this allows continuous recording function etc.
to continue operating.
Programmable dry contact (N/O or N/C)
Level detection method
100 msec or more
Make: 700 Ω or less
Break: 3 kΩ or more
20 mA or less
5 VDC or less (between open terminals)
600 Ω
300 mVrms (with 600 Ω termination)
Form C dry contact (N/O or N/C)
24 VAC, 1 A (resistive load)
24 VDC, 1 A (resistive load)
Minimum overload (AC/DC): 100mV, 0.1mA
- 15 -
https://www.aiphone.net/
AIPHONE CO., LTD., NAGOYA, JAPAN
Issue Date: Feb.2019 FK2452
P0219 RQ 61265

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents