Siemens SITRANS WW100 Operating Instructions Manual page 14

Weighfeeders
Hide thumbs Also See for SITRANS WW100:
Table of Contents

Advertisement

10. Save application data [see
11. Remove card and store for backup.
Switch drives
Follow these steps to switch between Command Data Set (CDS) and Drive Data Set
(DDS) parameters.
1. Press and hold
indicated by the drive number (see
2. Press
P0003 - Expert mode
P0003 must be set to EXPERT MODE to access/modify parameter settings .
1. Set S110 display to drive number 01 (see
2. Use
3. Press
4. Press
5. Use
6. Press
P1113 - Belt direction
P0003 must be set to EXPERT MODE to access/modify parameter settings (see
Note:
P0003 - Expert mode on page 10
If the belt is travelling in reverse, change P1113 setting to alternate value.
1. Set S110 display to drive number 02 (see
2. Use
3. Press
4. Press
5. Use
6. Press
Page 10
SITRANS WW100 - OPERATING INSTRUCTIONS
P0977 - Save to Micro Memory Card (MMC) on page 11
and use
to confirm selection. Display will stop flashing.
or
arrows to navigate to P0003.
so the current parameter value is displayed.
to activate edit mode (display will flash).
and
to set the value to 3.
and hold for 3 seconds to save.
).
or
arrows to navigate to P1113.
so the current parameter value is displayed.
to activate edit mode (display will flash).
and
to set the value to either 0 or 1 (whichever is the alternate).
and hold for 3 seconds to save.
or
arrows to access the alternate drive, as
S110 Display on page 9
Switch drives on page 10
Switch drives on page 10
].
).
).
).