Parameters Table; Logics Table - BFT DEIMOS BT A 600 Installation And User Manual

Actuator for rack sliding gates
Hide thumbs Also See for DEIMOS BT A 600:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12
TABLE "A" - PARAMETERS
TRIMMER
Parameter
Automatic
T1
closing time [s]
T2
Leaf force [%]
Slow-down
T3
distance [%]
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
TABLE "B" - LOGICS
DIP
Logic
Photocells
1
during closing
2
BAR / 8K2
3
Fast closing
Block pulses
4
during opening
Open in other
5
direction
Transmitter
6
programming
Safety device
7
testing
8
3-step logic
INSTALLATION MANUAL
+
+
min.
max.
Waiting time before automatic closing.
0
120
NOTE: Set to 0 if not used.
Force exerted by leaf/leaves.This is the percentage of force delivered, beyond the force stored during the
autoset cycle (and subsequently updated), before an obstacle alarm is generated.
10
90
WARNING: It affects impact force directly: make sure that current safety requirements are met
with the set value (*). Install anti-crush safety devices where necessary.
Set opening slow-down speed as a percentage of total travel. This distance is travelled at low speed.
5
50
NOTE: When this parameter is edited, a new Autoset cycle must be run to confirm it.
Cross out
Default
Description
setting used
In the event beam is broken, photocell operation is disabled during opening. During closing,
ON
movement is reversed immediately.
OFF
When beam is broken, photocells are active during both opening and clo-
OFF
sing. When beam is broken during closing, movement is reversed only once the
photocell is cleared.
Input configured as Bar 8k2 (Fig.D, ref.5). Input for resistive edge 8K2.
ON
The command reverses movement for 2 sec.
OFF
Input configured as Bar, safety edge (Fig.D, ref.4).
OFF
The command reverses movement for 2 sec..
ON
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
OFF
OFF
Logic not enabled
ON
The start pulse has no effect during opening.
OFF
OFF
The start pulse has effect during opening.
ON
Reverses movement of leaf in opposite direction to standard operation. (Fig.J, ref.2).
OFF
OFF
Standard operating mode. (Fig.J, ref.1).
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already
been memorized in standard mode via the radio menu.
2- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
ON
The receiver exits programming mode after 10 sec.: you can use this time to enter other new
transmitters.
ON
This mode does not require access to the control panel.
IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
Disables wireless memorizing of transmitters and automatic addition of clones.
OFF
Transmitters are memorized only using the relevant Radio menu or automatically with replays.
IMPORTANT: Disables the automatic addition of new transmitters and clones
ON
Enables safety device testing on PHOT and BAR inputs
OFF
OFF
Safety device testing not enabled
Switches to 3-step logic; during closing, start
ON
reverses movement.
OFF
OFF
Switches to 4-step logic.
Description
CLOSED
DURING CLOSING
OPEN
DURING OPENING
AFTER STOP
DEIMOS BT A 400 - DEIMOS BT A 600 -
3 step
4 step
opens
opens
stop
closes
closes
stop +
stop +
TCA
TCA
opens
opens
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Deimos ultra bt a 400

Table of Contents