SYMPTOM
Large, lazy flame (orange
color) with black ash / soot
buildup on glass
Excessive fuel spilling over the
fire pot and/or excessive flame
Black soot on the side of the
house
Unit rumbles consistently
during burns
January 8, 2019
POSSIBLE CAUSE
Dirty appliance or venting
Poor fuel quality, high ash content.
Incorrect air-fuel adjustment
Excessive feeding
Feed Motor locked on
Dirty Appliance
Feed Motor locked on
Dirty Appliance
Exhaust termination cap too close to
the structure
Excessive feeding (incorrect air-fuel
ratio)
Too much fuel
Too much air
NOTE: Refer to Tuning section for more information, page 12.
7082-154E
CORRECTIVE ACTION
Clean unit including the fire pot, exhaust path, and
venting system
Purge old fuel and use higher quality / or brand of fuel
Adjust the trim (see trim adjustment section)
Adjust tuning per tuning instructions
Follow corrective action for feed motor not turning off
Clean unit including the fire pot, exhaust path, and
venting system
Follow corrective action for feed motor not turning off
Clean unit including the fire pot, exhaust path, and
venting system
Extend the termination further from the structure
Adjust the tuning (see tuning section)
Turn tuning down one number at a time
Turn tuning setting to one; one number at a time