Quadra-Fire TREKKER-CSB Installation Manual

Quadra-Fire TREKKER-CSB Installation Manual

Hide thumbs Also See for TREKKER-CSB:

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
TREKKER FREE STANDING PELLET
APPLIANCE
MODEL(S):
TREKKER-CSB
TREKKER-MBK
TREKKER-PBK
TREKKER-PDB
TREKKER-PFT
TREKKER-PMH
CAUTION
Check building codes prior to installation.
Installation MUST comply with local, regional, state
and national codes and regulations.
Consult local building, fire officials or authorities
having jurisdiction about restrictions, installation
inspection, and permits.
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
1
Installation Manual
Installation & Appliance Set-Up
NOTICE: DO NOT DISCARD THIS MANUAL
If the information in these instructions is
not followed exactly, a fire could result
causing property damage, personal
injury, or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
Do not over fire - If appliance or chimney connector
glows, you are over firing. Over firing will void your
warranty.
Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause house fire.
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down. Hot glass will
cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
fireplace.
Alert children and adults to hazards of high
temperatures
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other
flammable materials away.
Tested and approved for wood pellets only. Burning of
any other type of fuel voids your warranty.
To obtain a French translation of this manual, please contact
your dealer or visit
www.quadrafire.com
Pour obtenir une traduction française de ce manuel, s'il vous
plaît contacter votre revendeur ou visitez
7080-165D
WARNING
WARNING
CAUTION
NOTE
www.quadrafire.com
September 24, 2018

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire TREKKER-CSB

  • Page 1 APPLIANCE injury, or death. MODEL(S): • Do not store or use gasoline or other flammable TREKKER-CSB vapors and liquids in the vicinity of this or any other TREKKER-MBK appliance. • Do not over fire - If appliance or chimney connector TREKKER-PBK glows, you are over firing.
  • Page 2: Table Of Contents

    G. Pipe Selection Chart ..... . .16 Quadra-Fire is a registered trademark of Hearth & Home Technologies. September 24, 2018...
  • Page 3: Important Safety Information

    ASTM E1509-04, ULC S627-00, (UM) 84-HUD and ULC/ORD-C-1482. This manual describes the installation of the Quadra-Fire, Trekker pellet appliance. This appliance meets the 2020 U.S. Environmental Protection Agency’s crib wood emission limits for wood heaters sold after May 15, 2020. Under specific test conditions this appliance has been shown to deliver heat at rates ranging from 12,682 to 39,428 Btu/hr.
  • Page 4: Glass Specifications

    TREKKER FS C. Glass Specifications WARNING This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please Fire Risk contact your dealer for replacement glass. Hearth & Home Technologies disclaims any D. Electrical Rating responsibility for, and the warranty will be voided 115 VAC, 60 Hz, Start 2.9 Amps, Run 2.45 Amps by, the following actions: E.
  • Page 5: Getting Started

    TREKKER FS Install Guide Getting Started A. Design, Installation & Location Considerations Since pellet exhaust can contain ash, soot or sparks, you must consider the location of: 1. Appliance Location • Windows NOTICE: Check building codes prior to installation. • Air Intakes •...
  • Page 6: Tools And Supplies Needed

    TREKKER FS C. Inspect Appliance and Components WARNING • Open the appliance and remove all the parts and articles packed inside the Component Pack. Inspect all Risk of Fire! the parts and glass for shipping damage. • Damaged parts could impair safe operation. •...
  • Page 7: Install Checklist

    TREKKER FS E. Install Checklist ATTENTION INSTALLER: Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual. __________________________________________________________________________ Customer: ______________________________________________________________________ Date Installed: _______________________________________________________________________ Lot/Address: ________________________________________________________________...
  • Page 8: Dimensions And Clearances

    TREKKER FS Dimensions and Clearances A. Appliance Dimensions 5-13/16 in 3-13/16 in 3-5/8 in 3-5/8 in 10-3/8 in 10-3/8 in 14-1/16 in (147mm) (97mm) (357mm) (93mm) (93mm) (264mm) (264mm) 2-9/16 in (65mm) Figure 8.1 - Top View Figure 8.4 - Top View with Top Vent Adapter (TPVNT-3) and Offset Adapter (812-3570).
  • Page 9 TREKKER FS 28-3/4 in (730mm) 26-7/8 in (683mm) 27-1/8 in 27-1/8 in (688mm) (688mm) 25-3/8 in 25-3/8 in 19-9/16 in (646mm) (646mm) (497mm) 20 in (508mm) Figure 9.4 - Side View with Top Vent Adapter (TPVNT-6) and Figure 9.1 -Side View Offset Adapter (811-0720).
  • Page 10: Clearances To Combustibles (Us & Canada)

    TREKKER FS Installations with: B. Clearances to Combustibles (US & Canada) TPVNT-3 Top Vent Adapter with Heat Shield and Clean-out TPVNT-6 Top Vent Adapter with Clean-out 811-0720 (3” to 4”) Offset Adapter 812-3570 (3” to 6”) Offset Adapter Horizontal Through the Wall Inches Millimeters Vertical Installation Inches Millimeters...
  • Page 11: Hearth Pad Requirements (Ul & Ulc)

    TREKKER FS C. Hearth Pad Requirements (UL & ULC) USA INSTALLATIONS: A non-combustible floor protection is recommended Use a non-combustible floor protector, extending beneath extending beneath the flue pipe when installed with appliance and to the front, sides and rear as indicated. horizontal venting or under the Top Vent Adapter with Measure front distance “M”...
  • Page 12: Alcove

    TREKKER FS D. Alcove Figure 12.1 Figure 12.2 Minimum* Maximum Inches Millimeters Inches Millimeters A Height 1092 B Width 1016 C Depth D To Side Wall *All minimums listed are to a combustible surface. NOTE: • Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY.
  • Page 13: Vent Information

    TREKKER FS Vent Information A. Venting Termination Minimum Requirements Electrical Service Inside Corner FIXED FIXED OPEN CLOSED CLOSED OPEN J or K Termination Cap Air Supply Inlet Restricted Area Gas Meter Figure 13.1 All minimum clearances are listed with an Outside Air Kit (OAK) installed, unless otherwise noted in table below. Above Finish Grade (the grade surface must Above grass, top of plants, wood or any other 12 in.
  • Page 14: Avoiding Smoke And Odors

    TREKKER FS B. Avoiding Smoke and Odors Vent Configurations When installing a pellet appliance with a horizontal vent Negative Pressure, Shut-Down and Electrical Power configuration the frequency of power outages should be Failure considered: • Power outages during operation will cause the To reduce the probability of back-drafting or burn-back appliance to immediately turn off and may create in the pellet appliance during power failure or shut down...
  • Page 15: Negative Pressure

    • Range hoods Adapter, use Listed double wall flue connector. A • Combustion air requirements for furnaces, water Quadra-Fire Outside Air Kit (OAK-3) must be used with appliances and other combustion appliances manufactured home installations. • Clothes dryers 3. Residential: The 3 inch (76mm) vertical Top Vent •...
  • Page 16: Equivalent Feet Of Pipe

    TREKKER FS F. Equivalent Feet of Pipe WARNING The table below can help you calculate the equivalent feet of pipe which is a method used to determine pellet vent Vent surfaces get HOT, can cause burns size (Figure 16.1). if touched. Non-combustible shielding or guards may be required.
  • Page 17: Venting Systems

    CAN/CSA-B365 installations. Must use 3 or 4 inch (76-102mm) “L” or “PL” Listed pellet venting or Listed double wall pipe and a Quadra-Fire Outside Air Kit in mobile homes. NOTICE: CAUTION Please note that while the minimum clearance for...
  • Page 18: Vertical Into Existing Class A Chimney

    TREKKER FS B. Vertical into Existing Class A Chimney We recommend a minimum of 60 inches (1524mm) vertical, however above the eave is preferred. Rain Cap All three installations are approved for mobile home installations. Must use 3 or 4 inch (76 to 102mm) “L” or “PL” Listed pellet venting or Listed double wall pipe and Quadra- Flashing 12 in.
  • Page 19: Masonry

    TREKKER FS E. Masonry Fireclay Flue Liner Concrete Cap with airspace Flashing 1 in [25mm] clearance 1 in [25mm] clearnance with firestop 3 in [76mm] min to 6 in combustible material [152mm] Sheathing Clean-out cover Airtight clean-out door Non-combustible Hearth Pad Figure 19.1 F.
  • Page 20: Appliance Set-Up

    TREKKER FS Appliance Set-Up A. Leg Leveling System B. Outside Air Kit Instructions 1. Thread Allen bolts through nuts until flush (Figure CAUTION 20.1). The Allen bolts and nuts are included in the component pack inside the appliance firebox. Never draw outside combustion air from: 2.
  • Page 21: Top Vent Adapter Installation

    TREKKER FS C. Top Vent Adapter Installation 3 to 3 inch (76-76mm) Top Vent Adapter 3 to 6 inch (76-152mm) Top Vent Offset Adapter Installing the Top Vent Adapter 1. Put a layer of high temperature silicone on the 3 inch (76mm) exhaust outlet.
  • Page 22: Optional Log Set Placement Instructions

    TREKKER FS E. Optional Log Set Placement Instructions 2 PIECE LOG SET INSTALLATION 1. Place the left log as shown. There are 2 indentations in the bottom of the log to fit over the screw heads in the firebox (Figures 22.1 and 22.2). 2.
  • Page 23: Installation Of User Interface

    TREKKER FS F. Installation of User Interface Install battery (Figure 23.4) Bluetooth Key Plug the Bluetooth key into the appliance (Figure 23.1) Figure 23.3 NOTE: See user interface manual on how to operate the Figure 23.1 user interface. G. Power to Appliance and User Interface H.
  • Page 24: Mobile Home Installation

    TREKKER FS Mobile Home Installation You must use a Quadra-Fire Outside Air Kit for CAUTION installation in a mobile home. 1. An outside air inlet must be provided for the THE STRUCTURAL INTEGRITY OF THE MOBILE combustion air and must remain clear of leaves, debris, HOME FLOOR, WALL AND CEILING/ROOF MUST BE ice and/or snow.
  • Page 25: Reference Materials

    TREKKER FS Reference Materials A. Service and Maintenance Log Date of Service Performed By Description of Service September 24, 2018 7080-165D...
  • Page 26 TREKKER FS Date of Service Performed By Description of Service September 24, 2018 7080-165D...
  • Page 27: Accessories List

    Leveling Assembly 7000-000 Matte Black 812-0910 TREKKER FS Porcelain Black 1-00-0022 B. Accessories List 1-00-0020 Porcelain Dark Blue Paint Touch-Up Porcelain Frost 1-00-0021 TREKKER Service Parts 855-1450 Porcelain Mahogany Beginning Manufacturing Date: Jun 2018 Sienna Bronze TOUCHUP-CSB Ending Manufacturing Date: Active Power Cord 812-1180 Exhaust Probe...
  • Page 28 Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafire.com CAUTION DO NOT DISCARD THIS MANUAL...

Table of Contents