Siemens SIMATIC NET CP 5711 Operating Instructions Manual

Pg/pc - profibus
Hide thumbs Also See for SIMATIC NET CP 5711:

Advertisement

CP 5711
SIMATIC NET
PG/PC - PROFIBUS
CP 5711
Operating Instructions
12/2021
C79000-G8976-C283-08
Preface
Description of the device
Software installation
Hardware installation
Configuration
Technical specifications
Approvals
Dimension drawing
1
2
3
4
5
A
B

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET CP 5711

  • Page 1 CP 5711 Preface Description of the device SIMATIC NET Software installation Hardware installation PG/PC - PROFIBUS CP 5711 Configuration Technical specifications Operating Instructions Approvals Dimension drawing 12/2021 C79000-G8976-C283-08...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    • 2-pin, plug-in terminal strip for external 24 V power supply Please check that the consignment you have received is complete. If it is not complete, please contact your supplier or your local Siemens office. Validity of this documentation These operating instructions are valid for the following product: •...
  • Page 4 You will find this documentation on the Product Support pages on the Internet under the following entry link: Support (https://support.industry.siemens.com/cs/ww/en/ps) Enter the entry ID shown below of the relevant manual as the search item. • Configuration manual Commissioning PC Stations This provides you with detailed information on commissioning and configuring SIMATIC NET PC communications modules.
  • Page 5 HARDNET, SOFTNET, CP 5612, CP 5613, CP 5614, CP 5622 Industry Online Support In addition to the product documentation, you are supported by the comprehensive online information platform of Siemens Industry Online Support at the following Internet address: (https://support.industry.siemens.com/cs/de/en/) Apart from news, there you will also find: •...
  • Page 6 In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions form one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks.
  • Page 7 Preface SIMATIC NET glossary The SIMATIC NET glossary describes terms that may be used in this document. You will find the SIMATIC NET glossary in the Siemens Industry Online Support at the following address: (http://support.automation.siemens.com/WW/view/en/50305045) Decommissioning Shut down the device properly to prevent unauthorized persons from accessing confidential data in the device memory.
  • Page 8 Preface CP 5711 Operating Instructions, 12/2021, C79000-G8976-C283-08...
  • Page 9: Table Of Contents

    Table of contents Preface ..............................3 Description of the device ........................11 Product characteristics ....................... 11 PROFIBUS interface ......................13 Meaning of the LED display ....................14 Software installation ........................... 15 Installing the "SIMATIC NET PC Software" ................15 Uninstalling the "SIMATIC NET PC Software" ............... 16 Hardware installation ..........................
  • Page 10 Table of contents CP 5711 Operating Instructions, 12/2021, C79000-G8976-C283-08...
  • Page 11: Description Of The Device

    Description of the device Product characteristics Properties The CP 5711 is a communications processor for connecting PCs (personal computers) or PGs (programming devices) to PROFIBUS and MPI networks. The essential properties are as follows: • Transmission speeds up to 12 Mbps. •...
  • Page 12 Description of the device 1.1 Product characteristics Appearance The following figure shows the CP 5711 communications processor mounted on a 35 mm DIN rail: USB interface type B with USB cable LEDs DIN rail PROFIBUS interface with D-sub male connector Terminals for external 24 V power supply Ground connection (cannot be seen in the figure) CP 5711...
  • Page 13: Profibus Interface

    You will find information about the structure of a PROFIBUS network in the system manual "PROFIBUS Network Manual". The document is part of the Manual Collection. You will also find this on the Product Support pages under the following entry ID: 35222591 (https://support.industry.siemens.com/cs/ww/en/view/35222591) PIN assignment The D-sub female connector has the following pin assignment:...
  • Page 14: Meaning Of The Led Display

    Description of the device 1.3 Meaning of the LED display Meaning of the LED display LED display The meaning of the LED display is as follows: Labeling Status Meaning PWR USB (green) The CP is connected to an active USB connector There is no connection to an active USB connector PWR EXT (green) There is an additional power source connected to the CP via the external...
  • Page 15: Software Installation

    Install the software as described in the installation manual "SIMATIC NET PC Software". You will find this installation manual on the Product Support pages under the following entry ID: 77377602 (https://support.industry.siemens.com/cs/ww/en/view/77377602) You should also note the current information on the "SIMATIC NET PC software" on the Product Support pages: Support (https://support.industry.siemens.com/cs/ww/en/ps/15362/pm)
  • Page 16: Uninstalling The "Simatic Net Pc Software

    Uninstall the entire software package as described and recommended in the installation manual "SIMATIC NET PC Software". You will find the installation manual on the "SIMATIC NET PC Software" DVD or on the Product Support pages under the following entry ID: 77377602 (https://support.industry.siemens.com/cs/ww/en/view/77377602) CP 5711 Operating Instructions, 12/2021, C79000-G8976-C283-08...
  • Page 17: Hardware Installation

    Hardware installation Connecting to the PG/PC Safety notices WARNING EXPLOSION HAZARD When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure. To comply with EU Directive 2014/34 EU (ATEX 114), UK-Regulation SI 2016/1107 or the conditions of IECEx or CCC-Ex, the housing or cabinet must meet the requirements of at least IP54 (according to EN/IEC 60529, GB/T 4208) in compliance with EN IEC/IEC 60079-7, GB 3836.8.
  • Page 18 Hardware installation 3.1 Connecting to the PG/PC WARNING EXPLOSION HAZARD DO NOT OPEN WHEN ENERGIZED. WARNING Ambient temperature in the hazardous area At an ambient temperature of ≥ 60 °C, use heat-resistant cables designed for an ambient temperature at least 20 °C higher. The cable entries used on the enclosure must comply with the IP degree of protection required by EN IEC / IEC 600079-0, GB 3836.1.
  • Page 19 • Observe the device approvals applicable for your country. WARNING Unauthorized repair of devices in explosion-proof design Risk of explosion in hazardous areas • Repair work may only be performed by personnel authorized by Siemens. WARNING Impermissible accessories and spare parts Risk of explosion in hazardous areas •...
  • Page 20 Hardware installation 3.1 Connecting to the PG/PC Notes on parallel operation with other USB devices Note The use of other USB devices (for example a WebCam, bulk memory) on the PG/PC can impair the performance of the communications processor. Note Removing and inserting USB devices can cause functional disruptions on the USB interface.
  • Page 21: Hardware Compatibility

    Hardware installation 3.2 Hardware compatibility Removing the CP 5711 Delete existing configurations before you disconnect the communications processor from your PG/PC. You must also log off the communications processor reliably before you disconnect the communications processor from the PG/PC. Click the "Safely Remove Hardware" icon in the taskbar notification area.
  • Page 22: External Power Supply

    Hardware installation 3.3 External power supply External power supply WARNING Safety extra low voltage The equipment is designed for operation with a directly connectable safety extra low voltage (SELV) from a limited power source (LPS). (This does not apply to 100 V...240 V devices).
  • Page 23 Hardware installation 3.3 External power supply Requirements of the external power supply Use an external power supply with the following characteristics: • Rate voltage 24 VDC • Permitted range 22.8 to 25.2 VDC • Current consumption max. 300 mA • Safety extra low voltage (SELV) complying with IEC 60950-1 / EN 60950-1 / VDE 0805-1 Disconnection from the external power supply NOTICE First disconnect the USB connection...
  • Page 24: Installing On A Din Rail

    Hardware installation 3.4 Installing on a DIN rail Installing on a DIN rail Condition To mount the communications processor on a 35 mm DIN rail, you require an additional DIN rail holder. You can obtain this holder under the article number 6GK1 571-1AA00-0AH0. Safety notice NOTICE Improper mounting...
  • Page 25 Hardware installation 3.4 Installing on a DIN rail Procedure Upper DIN rail holder DIN rail Lower DIN rail holder with spring catch Spring DIN rail slider 1. Push the DIN rail holder into the profile on the rear of the CP. 2.
  • Page 26 Hardware installation 3.4 Installing on a DIN rail Removing the communications processor from the DIN rail WARNING EXPLOSION HAZARD Improper disassembly may result in a risk of explosion in hazardous areas. For proper disassembly, observe the following: • Before starting work, ensure that the electricity is switched off. •...
  • Page 27: Configuration

    Configuration Configuring To be able to configure the communications processor, the following engineering or configuration tools are available: • STEP 7 V5.5 • STEP 7 Professional (TIA Portal) • Communication Settings (COML S7) The steps involved are described in the "Commissioning PC Stations" manual or in the relevant online helps.
  • Page 28 Configuration CP 5711 Operating Instructions, 12/2021, C79000-G8976-C283-08...
  • Page 29: Technical Specifications

    Technical specifications Technical specifications of the CP 5711 Connection to PROFIBUS Amount Transmission speeds 9.6 kbps, 19.2 kbps, 45.45 kbps, 93.75 kbps, 187.5 kbps, 500 kbps, 1.5 Mbps, 3 Mbps, 6 Mbps, 12 Mbps Design 9-pin D-sub female connector with screw locking mechanism RS-485 (ungrounded within the SELV limits) Properties...
  • Page 30 Technical specifications Technical specifications of the CP 5711 Rapid temperature change when damp +25...+55°C at 97% no condensation (EN 60068-2-30) Rapid temperature change (EN 60068-2-14) -40 ... +70°C, 2 cycles Vibration, operating Frequency 10 ... 58 Hz 0.075 mm amplitude (EN 60068-2-6) Frequency 58 ...
  • Page 31: Approvals

    You will find the EU Declaration of Conformity for this communications processor on the Product Support pages under the following entry ID: 58826997 (https://support.industry.siemens.com/cs/ww/en/view/58826997) Electromagnetic compatibility - EMC directive The communications processor meets the requirements of the EU Directive 2014/30/EU (EMC Directive).
  • Page 32 Siemens plc, Manchester M20 2UR You can find the current UK Declaration of Conformity for this product on the Internet pages under Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/15361/cert). The SIMATIC NET products described in this document meet the requirements of the following directives: •...
  • Page 33 The markings of the electrical devices are: II 3 G Ex ec IIC T4 Gc DEKRA 18ATEX0027 X DEKRA 21UKEX0003 X IECEx DEK 18.0019X Importer UK: Siemens plc, Manchester M20 2UR (Ex na IIC T4 Gc, not on the nameplate) CCC-Ex certificate:...
  • Page 34 Approvals C-TICK approval The communications processor meets the requirements of the Australian AS/NZS 3548 standard according to EN 61000-6-3. cULus Approval for Information Technology Equipment cULus Listed I. T. E. Underwriters Laboratories Inc. complying with • UL 60950-1 (Information Technology Equipment) •...
  • Page 35 Approvals FCC approval This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 36 Approvals CP 5711 Operating Instructions, 12/2021, C79000-G8976-C283-08...
  • Page 37: Dimension Drawing

    Dimension drawing CP 5711 front view and view from above All dimensions in millimeters CP 5711 Operating Instructions, 12/2021, C79000-G8976-C283-08...
  • Page 38 Dimension drawing Front view and side view of the DIN rail holder All dimensions in millimeters. CP 5711 Operating Instructions, 12/2021, C79000-G8976-C283-08...

Table of Contents