Position - Furuno FM-8800D Service Manual

Vhf radiotelephone
Hide thumbs Also See for FM-8800D:
Table of Contents

Advertisement

4.3.5 POSITION

This is to select a positioning data either by MANUAL or AUTO. Sentences to receive
are IEC61162-1 (equal to NMEA Ver.3): GGA > RMC > GNS > GLL and ZDA. When
manual input position, it changes to GPS data automatically when inputted the position
data from GPS and so on. Then, when using GPS data, manual input is not available.
The related setting is [MENU] -> POSITION OLDER.
Procedure
1. Select [MENU] -> POSITION and press [ENT] key.
2. Select INPUT TYPE, either AUTO or MANUAL, and press [ENT] key.
If a positioning data is inputted, select AUTO. When MANUAL is set up, input your
own ship's position and positioning time.
* SETUP MENU *
POSITION
PRINT OUT
VOLUME
SYSTEM
How to operate IEC61162-1
1. UTC shown on VHF display is an indication of ZDA time. When there is no ZDA
available, time available in GGA > RMC > GNS > GLL will be used.
2. ZDA is used to indicate Date/Time on a printed-out self-test result. When ZDA is
not available, time available in a GGA > RMC > GNS > GLL, and date available
in a ZDA > RMC will be used.
3. Matching talker: GP > LC > DE > II > IN > EC > TR > LA > OM
4. Data can be received regardless of the availability of expansion field.
Check-Sum
Sentence
Yes
GGA
Used
RMC
Used
GNS
Used
GLL
Used
ZDA
Used
GPS quality indicator
0 = fix not available or invalid
1 = GPS SPS mode, fix valid
2 = differential GPS, SPS mode, fix valid
3 = GPS PPS mode, fix valid
4 = Real Time Kinetic. System used in RTK mode
with fixed integers
5 = Float RTK. Satellite system used in RTK mode
with floating fingers
6 = Estimated (dead reckoning) mode
7 = Manual input mode
8 = Simulator mode
[ENT]
INPUT TYPE: AUTO
LAT : 35°10' 0
LON : 135°10' 0
TIME : 11:10
Table 4.3.2 Operation of the IEC61162-1
GPS Quality Indicator
No
1, 2, 3
Used
Used
Used
Used
Used
Used
4-18
4.3 System Setting: User Menu
[ENT]
AUTO
MANUAL
Status
Mode Indicator
Valid (A)
A, D, E, M
Used
Used
Used
Used
Used
Mode indicator:
A = Autonomous mode
D = Differential mode
E = Estimated (dead reckoning) mode
M = Manual input mode
S = Simulator mode
N = Data not valid