MAINTENANCE
1-6

Procedures for Replacing Consumables Used on the Vacuum Pump

1-6-1

Periodic Checks

Inspect consumables periodically by referring to the table below once you start to use the
machine.
See the section 1-6-2, "List of Consumables" for details of consumables.
Inspection
frequency
Every 10000 h
Cup packing
Intake valve
Every 10000 h
Exhaust valve
Every 10000 h
Gasket
Every 10000 h
O-ring
Every 10000 h
Intake valve interference
Every 10000 h
prevention rubber
Measure of replacement
1) Cup packing ------------------------------------------ If vacuum pressure is low.
2) Intake and exhaust valves ------------------------ If they are deformed, cracked or bent.
3) Gasket and O-ring ---------------------------------- If they are hardened, cracked, or elongated.
4) Intake valve interference prevention rubber -- If it is cracked or deteriorated.
If air, solvent, powder, etc. enter into the pump, the life of consumables
will be short to be replaced.
1-6-2

List of Consumables

The lives of consumables below vary greatly according to the conditions of use.
Cup packing
Intake and exhaust valves
Gasket
O-ring (P-10)
Intake valve interference prevention rubber
O-ring (S-67)
3V3C-E-MMD01-A02-01
Items
Inspection and maintenance
Check for performance deterioration
Check for deformation
Check for deformation
Check for breakage and leak
Check for breakage and leak
Check for deformation and deteriora-
tion
NOTICE
Name
Section 1 INSPECTION
With vacuum gage
Visual inspection
Visual inspection
Visual inspection
Visual inspection
Visual inspection
Quantity
Material
Special Teflon
2
SUS
Each 2
FPM
2
FPM
4
2
SI
2
FPM
1
Method