Outdoor Video Surveillance UPS

Installation Guide

Models Include:
ReServ1WP
- Twelve (12) true sine wave regulated 24VAC outputs
and Four (4) regulated 12VDC outputs.
- 4A total supply current @ 24VAC and 2A total supply current @ 12VDC.
- PTC protected power-limited outputs.
ReServ2WP
- Sixteen (16) true sine wave regulated 24VAC outputs.
- 4A total supply current.
- PTC protected power-limited outputs.
ReServ3WP
- Sixteen (16) regulated 12VDC outputs.
- 8A total supply current.
- PTC protected power-limited outputs.
Rev. 082610
More than just power.
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ReServ1WP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Altronix ReServ1WP

  • Page 1: Installation Guide

    Outdoor Video Surveillance UPS Installation Guide Models Include: ReServ1WP - Twelve (12) true sine wave regulated 24VAC outputs and Four (4) regulated 12VDC outputs. - 4A total supply current @ 24VAC and 2A total supply current @ 12VDC. - PTC protected power-limited outputs.
  • Page 2: Specifications

    - up to two (2) 12VDC/12AH batteries. • Audio AC Fail and Battery Fail indicator. Stand-by Specifications: ReServ1WP - 4A (100VA) load at 24VAC and 2A load at 12VDC max. Stand-by Batteries ReServ2WP - 4A (100VA) max. load at 24VAC ReServ3WP - 8A (100VA) max.
  • Page 3: Installation Instructions

    8. ReServ3WP only - Adjust voltage for every two (2) outputs using the corresponding trimpot(s) on the board prior to connecting devices. 9. Connecting cameras/devices: ReServ1WP: Connect 12VDC cameras/devices to the terminals marked [P 1-4], [N 1-4] (Fig. 1, pg. 5). Connect 24VAC cameras/devices to the terminals marked [5-16] (Fig. 1, pg. 5).
  • Page 4: Led Diagnostics

    LED Diagnostics: Power Supply Board Red (DC) Green (AC1) Power Supply Status Normal operating condition. Loss of AC. Stand-by battery is supplying power. No DC output. Loss of AC. Discharged or no stand-by battery. No DC output. ReServ Board LED State Unit Status –...
  • Page 5 Fig. 1 - ReServ1WP and ReServ2WP Ground Lug Input -- 24VDC + Unswitched 115VAC 60Hz, 3.5A power mains (non power-limited) power- limited + BAT -- -- DC + Supervised - Non power-limited 12VDC Rechargeable Battery (order separately) Note: Two (2) 12VDC rechargeable batteries connected in series required.
  • Page 6 Fig. 2 - ReServ3WP Ground Lug Non power-limited --- 24VDC + Unswitched 115VAC 60Hz, 3.5A power mains (non power-limited) power- limited 1,2 V adjust 3,4 V adjust 5,6 V adjust 7,8 V adjust 9,10 V adjust 11,12 V adjust 13,14 V adjust 15,16 V adjust 1 OUT 2 3 OUT 4...
  • Page 7: Wall Mount Installation

    Pole Mounting Using Optional Pole Mount Kit PMK1 (not included): Note: In order to properly mount ReServ WP on a pole using Altronix PMK1, additional holes need to be drilled in the enclosure’s flanges, so the distance between those holes is 10”.
  • Page 8 17.53” x 15.3” x 6.67” (445.3mm x 388.6mm x 169.4mm) Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty | Made in U.S.A. MEMBER IIReServWP...

This manual is also suitable for:

Reserv2wpReserv3wp

Table of Contents