Outdoor Video Surveillance UPS

Installation Guide

Models Include:
ReServ1WPV
- Twelve (12) true sine wave regulated 24VAC outputs
and Four (4) regulated 12VDC outputs.
- 4A total supply current @ 24VAC and 2A total supply current @ 12VDC.
- PTC protected power-limited outputs.
ReServ2WPV
- Sixteen (16) true sine wave regulated 24VAC outputs.
- 4A total supply current.
- PTC protected power-limited outputs.
ReServ3WPV
- Sixteen (16) regulated 12VDC outputs.
- 8A total supply current.
- PTC protected power-limited outputs.
More than just power.™

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ReServ1WPV and is the answer not in the manual?

Questions and answers

Summary of Contents for Altronix ReServ1WPV

  • Page 1: Installation Guide

    Outdoor Video Surveillance UPS Installation Guide Models Include: ReServ1WPV - Twelve (12) true sine wave regulated 24VAC outputs and Four (4) regulated 12VDC outputs. - 4A total supply current @ 24VAC and 2A total supply current @ 12VDC. - PTC protected power-limited outputs.
  • Page 2: Specifications

    • Low voltage input and Shutdown LED indicators. • Audio AC Fail and Battery Fail indicator. Stand-by Specifications: ReServ1WPV - 4A (100VA) load at 24VAC and 2A load at 12VDC max. Stand-by Batteries ReServ2WPV - 4A (100VA) max. load at 24VAC ReServ3WPV - 8A (100VA) max.
  • Page 3: Left Panel

    9. Connecting cameras/devices: ReServ1WPV - Connect 12VDC cameras/devices to terminals marked [P 1-4, N 1-4] (Fig. 2, pg. 5). Connect 24VAC cameras/devices to terminals marked [5-16] (Fig. 2, pg. 5). ReServ2WPV - Connect 24VAC cameras/devices to terminals marked [1-16] (Fig. 2, pg. 5).
  • Page 4: Terminal Identification

    LED Diagnostics: Power Supply Board Red (DC) Green (AC1) Power Supply Status Normal operating condition. Loss of AC. Stand-by battery supplying power. No DC output. Loss of AC. Discharged or no stand-by battery. No Dc output. ReServ Board LED State Unit Status ------ Normal operating condition.
  • Page 5 Fig. 2 - ReServ1WPV and Reserv2WPV Input --- 24VDC + Unswitched 220VAC 50Hz, 2A power mains (non power-limited) power- LOW BATTERY limited SHUTDOWN For outputs configuration refer to Step 9, Pg. 3 of Installation Instructions 10 11 12 13 14 15 16...
  • Page 6 Fig. 3 - ReServ3WPV Input --- 24VDC + Unswitched 220VAC 50Hz, 2A power mains (non power-limited) power- limited 1,2 V adjust 3,4 V adjust 5,6 V adjust 7,8 V adjust 9,10 V adjust 11,12 V adjust 13,14 V adjust 15,16 V adjust 1 OUT 2 3 OUT 4 5 OUT 6...
  • Page 7: Wall Mount Installation

    This installation should be made by qualified service personnel. This product contains no serviceable parts. PMK1 is in- tended for use with Altronix outdoor rated power supplies or accessories housed in WP1, WP2, WP3 and WP4 enclosures. Brackets are designed for use with the Wormgear Quick Release Straps (two included).
  • Page 8: Enclosure Dimensions

    (H x W x D approximate) 17.375” x 12” x 6.5” (441.3mm x 304.8mm x 165.1mm) Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 website: www.altronix.com, e-mail: info@altronix.com.