Outdoor Video Surveillance UPS
Installation Guide
Models Include:
ReServ1WPV
- Twelve (12) true sine wave regulated 24VAC outputs
and Four (4) regulated 12VDC outputs.
- 4 amp total supply current @ 24VAC and 2 amp total supply current @ 12VDC.
- PTC protected power-limited outputs.
ReServ2WPV
- Sixteen (16) true sine wave regulated 24VAC outputs.
- 4 amp total supply current.
- PTC protected power-limited outputs.
ReServ3WPV
- Sixteen (16) regulated 12VDC outputs.
- 8 amp total supply current.
- PTC protected power-limited outputs.
More than just power.™

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ReServ1WPV and is the answer not in the manual?

Questions and answers

Summary of Contents for Altronix ReServ1WPV

  • Page 1: Installation Guide

    Outdoor Video Surveillance UPS Installation Guide Models Include: ReServ1WPV - Twelve (12) true sine wave regulated 24VAC outputs and Four (4) regulated 12VDC outputs. - 4 amp total supply current @ 24VAC and 2 amp total supply current @ 12VDC.
  • Page 2: Specifications

    • Audio AC Fail and Battery Fail indicator. Battery Backup: Additional Features: • Built-in charger for sealed lead acid or gel type batteries. • True sine wave regulated AC outputs (ReServ1WPV & • Automatic switchover to stand-by battery ReServ2WPV). Regulated DC outputs (ReServ1WPV & when AC fails.
  • Page 3: Installation Instructions

    9. Connecting cameras/devices: ReServ1WPV - Connect 12VDC cameras/devices to terminals marked [P 1-4, N 1-4] (Fig. 2, pg. 5). Connect 24VAC cameras/devices to terminals marked [5-16] (Fig. 2, pg. 5). ReServ2WPV - Connect 24VAC cameras/devices to terminals marked [1-16] (Fig. 3, pg. 6).
  • Page 4 LED Diagnostics (cont’d): ReServ Board LED State Unit Status ------ Normal operating condition. Output LEDs ------ Loss of 24VACand/or 12VDC output power. ------ Stand-by batteries are low. Low Battery ------ Normal operating condition. ------ Loss of 24VACand/or 12VDC output power. Discharged stand-by battery. Shutdown ------ Normal operating condition.
  • Page 5 Fig. 2 - ReServ1WPV Input --- 24VDC + unswitched 220VAC 60Hz, 2 amp power mains (non power-limited) power- limited LOW BATTERY SHUTDOWN 10 11 12 13 14 15 16 12VDC 24VAC Non-power limited Power- Power-Limited Outputs Limited Outputs CAUTION: Risk of explosion if battery is replaced by an Green incorrect type.
  • Page 6 Fig. 4 - ReServ2WPV Input --- 24VDC + unswitched 220VAC 50Hz, 2 amp power mains (non power-limited) power- limited LOW BATTERY SHUTDOWN 10 11 12 13 14 15 16 24VAC Power-Limited Outputs Non-power limited CAUTION: Risk of explosion if battery is replaced by an incorrect type.
  • Page 7 Fig. 5 - ReServ3WPV Input --- 24VDC + unswitched 220VAC 50Hz, 2 amp power mains (non power-limited) power- limited 1,2 V adjust 3,4 V adjust 5,6 V adjust 7,8 V adjust 9,10 V adjust 11,12 V adjust 13,14 V adjust 15,16 V adjust 1 OUT 2 3 OUT 4...
  • Page 8 (H x W x D) (approximate) 17.375” x 12” x 6.5” (441.3mm x 304.8mm x 165.1mm) Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 website: www.altronix.com, e-mail: info@altronix.com, Made in U.S.A.