Emi And Environmental Type Tests - Siemens RUGGEDCOM RS416P Installation Manual

Hide thumbs Also See for RUGGEDCOM RS416P:
Table of Contents

Advertisement

Chapter 6
Certification
Section 6.3

EMI and Environmental Type Tests

The RS416P has passed the following EMI and environmental tests.
IEC 61850-3 Type Tests
Test
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-29
IEC 61000-4-11
IEC 61000-4-12
IEC 61000-4-16
IEC 61000-4-17
38
Description
ESD
Radiated RFI
Burst (Fast Transient)
Surge
Induced (Conducted) RFI
Magnetic Field
Voltage Dips and Interrupts
Damped Oscillatory
Mains Frequency Voltage
Ripple on DC Power Supply
Enclosure
Contact
Enclosure Air
Enclosure ports
Signal ports
DC Power ports
AC Power ports
Earth
ground ports
Signal ports
± 4 kV line-to-earth, ± 2 kV line-to-line
DC Power ports
± 2 kV line-to-earth, ± 1 kV line-to-line
AC Power ports
± 4 kV line-to-earth, ± 2 kV line-to-line
Signal ports
DC Power ports
AC Power ports
Earth
ground ports
Enclosure ports
DC Power ports
30% for 0.1 s, 60% for
0.1 s, 100% for 0.05 s
AC Power ports
30% for 1 period, 60% for 50 periods
100% for 5 periods,
100% for 50 periods
Signal ports
2.5 kV common, 1 kV
differential mode @ 1 MHz
DC Power ports
2.5 kV common, 1 kV
differential mode @ 1 MHz
AC Power ports
2.5 kV common, 1 kV
differential mode @ 1 MHz
Signal ports
30 V Continuous, 300 V for 1 s
DC Power ports
30 V Continuous, 300 V for 1 s
DC Power ports
Test Levels
± 8 kV
± 15 kV
20 V/m
± 4 kV @ 2.5 kHz
± 4 kV
± 4 kV
± 4 kV
10 V
10 V
10 V
10 V
100 A/m
1000 A/m for 3 s
± 15%
EMI and Environmental Type Tests
RUGGEDCOM RS416P
Installation Guide
Severity Levels
4
4
a
Note
a
Note
4
4
4
4
3
4
3
3
3
3
a
Note
5
3
3
3
4
4
4

Advertisement

Table of Contents
loading

Table of Contents