Minimum Distances - Tecfluid Series LT Instruction Manual

Level gauge
Table of Contents

Advertisement

6.1

Minimum distances

It is important to take in account some distances that must be kept in order to remove the
float due to a change in density or for maintenance purposes.
Distance LMS between the lowest side of the level gauge and the floor must be kept longer
or equal to LD distance.
On the other hand, the lower dimension LD, LP or LPV of series LT level gauges is variable
depending on the working liquid density. The lower the density, the longer the dimension.
Liquid
Model
density (kg/l)
0,55 ... 0,59
LT ... LTL /
0,60 ... 0,91
AISI 316L
≥ 0,92
0,60 ... 0,79
LT ... LTL /
0,80 ... 0,89
PVC
≥ 0,90
LT ... LTL /
≥ 0,70
PP
0,80 ... 0,89
LT ... LTL /
0,90 ...0,99
PVDF
1,00 ... 1,19
≥ 1,20
Lower dimension
Without
With drain
drain (LD)
(LP)
430
445
340
355
260
275
400
310
240
240
415
340
290
240
With drain +
Without
valves (LPV)
vent (LS)
590
500
130
420
525
435
150
365
365
150
540
465
150
415
365
8
Upper dimension
With vent
With vent +
(LV)
valve (LVV)
155
300
140
265
165
290
165
290

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents