8
LEVEL READING
For level gauges with a glass tube (LT models), the value of the level is read on the scale at
the height of the top of the external follower. For level gauges with indication by means of
magnetic strips (LTL models), the reading is taken where the strips change from red to
white.
LTL models can be supplied with graduated scale on request.
Reading
9
FLOAT TYPES
Liquid density
Material
Titanium
0.55 ... 0.83
Titanium
0.68 ... 0.83
Titanium
0.77 ... 0.83
EN 1.4404
0.84 ... 2.00
EN 1.4404
0.84 ... 2.00
EN 1.4404
0.84 ... 2.00
PVC
0.60 ... 2.00
PP
0.70 ... 2.00
PVDF
0.80 ... 2.00
Maximum
kg/l
pressure
PN40
PN63
100 bar max.
PN40
PN63
PN100
PN10
PN10
PN10
EN 1.4404
EN 1.4404
18
Reading
Titanio
Plástico
Titanium
Plastic