Self-Assembled Cable - Siemens RF180C Operating Instructions Manual

Simatic ident, rfid systems, communication module
Table of Contents

Advertisement

Connecting cable to the reader

10.2 Self-assembled cable

10.2
Self-assembled cable
A reader/SLG connector plug with screw terminals is available for users who want to
individually assemble their own cables (refer to the relevant system manual). Cables and
reader/SLG connector plugs can be ordered from the catalog "ID 10 Industrial Identification
Systems".
Cable structure
You will need cables of the following specifications for self-assembled cables:
● 7 x 0.25 mm
● LiYC11Y 7 x 0.25
Connectors
M12 connectors can be obtained from the relevant specialist dealers (e.g. Binder).
Pin assignment
The pin assignment is listed in the following table.
Table 10- 4
M12 connector (male)
62
2
Pin assignment
Pin
Signal
1
1L+ (+ 24 V)
2
−RxD
3
0 V
4
RxD
5
TxD
6
−TxD
7
Free
8
Functional
ground
(PE)/shield
Operating Instructions, 12/2012, J31069-D0177-U001-A6-7618
Core color
Note data sheet
provided by cable
manufacturer
RF180C communication module