Parameterization

5.2 Assigning device names to the I/O device

Follow the steps below to configure the RF180C on PROFINET IO with the TIA Portal:
1. Start the TIA Portal in the project view and call the menu command "Options > Install
2. In the dialog that opens, select the GSDML file you want to install and confirm with
3. Create a new project.
4. Configure the RF180C in the Network view.
5. Set the parameters for the RF180C.
6. Save the configuration, or download it to the PROFINET IO controller.
You will find further information in the sections "Assigning device names to the I/O device
(Page 32)" and "Configuration parameters of the RF180C (Page 36)".
5.2
Assigning device names to the I/O device
Introduction
Each PROFINET IO device is assigned a unique device ID by the manufacturer (MAC
address). Each RF180C IO device is addressed by its device name in the configuration and
user program.
For detailed information on addressing in PROFINET IO, refer to the "SIMATIC PROFINET
system description (http://support.automation.siemens.com/WW/view/en/19292127/0/en)".
Requirements
● RF180C communication module
● To assign the device name to the communications module, one of the following
● There must be no connection to the CPU.
32
device description files".
"Install".
Result: The RF180C is displayed in the device configuration under "Other field devices >
PROFINET IO > Ident Systems > Siemens AG > SIMATIC RFID".
connections is necessary:
– Online PROFINET connection from the PG to the IO device
– Ethernet connection from a PC to the IO device (using the "Primary Setup Tool (PST)"
software)