Parameterization
5.4 Input parameters for RF180C
Input parameters for RF180C with FB 55
Assignment is made in UDT 11.
Table 5- 3
Input parameters for RF180C with FB 55
Address
Name
0.0
+0.0
ASM_address
+2.0
ASM_channel
+4.0
command_DB_number
+6.0
command_DB_address
+8.0
MDS_control
+9.0
reserved0
+9.1
RESET_long
+10.0
MOBY_mode
+11.0
scanning_time
+12.0
option_1
+13.0
distance_limiting
+14.0
multitag
+15.0
field_ON_control
+16.0
field_ON_time
Special information on the input parameters for RF180C with FB55 in conjunction with the
readers RF620R/RF630R can be found in the "Configuration manual RF620R/RF630R
(http://support.automation.siemens.com/WW/view/en/33287195)".
38
Type
Initial value
STRUCT
INT
256
INT
1
INT
58
INT
0
BYTE
B#16#1
BOOL
FALSE
BOOL
TRUE
BYTE
B#16#7
BYTE
B#16#0
BYTE
B#16#0
BYTE
B#16#F
BYTE
B#16#1
BYTE
B#16#0
BYTE
B#16#0
Input: Base address of the
communication module (cyclic word)
Input: Number of the channel (1 to 4)
Input: Command data block number
Input: Start address of data in the
BEDB
Input: Presence check and tag control
(0, 1)
Input: true: long RESET telegram, only
for MOBY mode 5
Input: MOBY mode
(6 and 7 only)
Input: Scanning time for MOBY D/U
Input: RESET command option 1
Input: Range limit
Input: max. number of tags in field
Input: BERO mode
Input: BERO time
Operating Instructions, 12/2012, J31069-D0177-U001-A6-7618
Comment
RF180C communication module