Transferring the device name to the communication module
Follow the steps below to transfer the device name using STEP 7:
1. In HW Config, select the menu command "PLC > Ethernet > Edit Ethernet node".
2. Click the "Browse" button for modules that can be accessed online. This will display all
3. Select the required RF180C and click "OK".
4. Assign a device name and click the "Assign name" button.
Follow the steps below to transfer the device name with the TIA Portal:
1. In project navigation, select the menu command "Online access > <your online access> >
2. Select the required RF180C and click the entry "Online & Diagnostics" in the folder of the
RF180C communication module
Operating Instructions, 12/2012, J31069-D0177-U001-A6-7618
accessible PROFINET IO controllers and IO Devices complete with MAC address, IP
address (where applicable), device name and device type.
The device name must be unique within the system and must match the HW Config
configuration.
Update accessible devices".
The available devices are displayed.
selected device.
5.2 Assigning device names to the I/O device
Parameterization
33