CompactLogix 5380 Controllers

Specifications

This table lists a subset of controller specifications. For a complete list of specifications, see the CompactLogix 5380 and Compact GuardLogix5380
Controllers Technical Data, publication
Attribute
Temperature, operating
IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Na, Operating Thermal Shock)
Temperature, surrounding air, max
Enclosure Type rating
Voltage ratings
MOD Power voltage range
MOD Power current, max
MOD Power inrush
(1)
MOD Power Passthrough
MOD Power current rating, max
(2)
SA Power voltage ranges
(2)
SA Power current, max
,
(2)
(3)
SA Power Passthrough
(2)
SA Power current rating, max
Isolation voltage
Wire size
Insulation stripping length
Terminal block torque
North American temperature code
ATEX temperature code
IECEx temperature code
(1) Maximum level of MOD Power current that the controller can pass through to the next module in the system. The specific level of current passed through varies based on system configuration.
(2) SA power specifications are based on the number and type of Compact 5000™ I/O modules used in the system. If the set of I/O modules that are used in the system require AC and DC voltage, you must install a 5069-FPD field
potential distributor to separate the module types.
(3) Maximum level of SA Power current that the controller can pass through to the next module in the system. The specific level of current passed through varies based on system configuration.
14
5069-TD002.
5069-L306ER, 5069-L306ERM, 5069-L310ER, 5069-L310ER-NSE, 5069-L310ERM, 5069-L320ER, 5069-L320ERM,
5069-L330ER, 5069-L330ERM, 5069-L340ER, 5069-L340ERM, 5069-L350ERM, 5069-L380ERM, 5069-L3100ERM
0 °C < Ta < +60 °C
(+32 °F < Ta < +140 °F)
60 °C (140 °F)
None (open-style)
18...32V DC
450 mA
850 mA for 125 ms
9.55 A @ 18...32V DC
10 A
Do not exceed 10 A current draw at the MOD power RTB.
0...32V DC
0...240V AC, 47...63 Hz
ATEX/IECEX, 125V AC max
10 mA (DC power)
25 mA (AC power)
9.95 A @ 0...32V DC
9.975 A @ 0...240V AC, 47...63 Hz
ATEX/IECEX, 125V AC max
10 A
Do not exceed 10 A current draw at the SA power RTB.
300V (continuous), Basic Insulation Type, SA, and MOD Power to Backplane
300V (continuous), Basic Insulation Type, SA to MOD Power
300V (continuous), Basic Insulation Type, Ethernet to Backplane
300V (continuous), Double Insulation Type, Ethernet to MOD Power
300V (continuous), Double Insulation Type, Ethernet to SA Power
50V (continuous), Functional Insulation Type, Ethernet to USB
300V (continuous), Basic Insulation Type, USB to Backplane
300V (continuous), Double Insulation Type, USB to MOD Power
300V (continuous), Double Insulation Type, USB to SA Power
No isolation between Ethernet ports
Type tested at 1500V AC for 60 s
5069-RTB4-SCREW, 5069-RTB6-SCREW connections:
2
0.5...1.5 mm
(22...16 AWG) solid or stranded copper wire that is rated at 105 °C (221 °F), or greater, 3.5 mm (0.14 in.) max
diameter including insulation, single wire connection only
5069-RTB4-SPRING, 5069-RTB6-SPRING connections:
2
0.5...1.5 mm
(22...16 AWG) solid or stranded copper wire that is rated at 105 °C (221 °F), or greater, 2.9 mm (0.11 in.) max
diameter including insulation, single wire connection only
Ethernet connections:
Ethernet Cabling and Installation according to IEC 61918 and IEC 61784-5-2
5069-RTB4-SCREW, 5069-RTB6-SCREW connections: 12 mm (0.47 in.)
5069-RTB4-SPRING, 5069-RTB6-SPRING connections: 10 mm (0.39 in.)
5069-RTB4-SCREW & 5069-RTB6-SCREW: 0.4 N•m (3.5 lb•in)
5069-RTB4-SPRING & 5069-RTB6-SPRING: N/A
T4
T4
T4
Rockwell Automation Publication 5069-IN013D-EN-P - April 2018