Service Manual
Steps
4. Remove axial flow blade
Remove the nut fixing axial flow blade and then
remove the blade.
Remove the 6 screws fixing the motor and then
remove the motor.
Remove the 2 screws connecting the motor support
and chassis, and then loosen the stopper to remove
the motor support.
5. Remove
electric box
Remove the screws fixing the electric box sub-assy;
loosen the wire bundle; pull out the wiring terminals
and then pull the electric box upwards to remove it.
Installation and Maintenance
Procedure
axial flow fan
motor support
fan motor
electric box