  • ENGLISH, page 13
DANGER
Tipping the waste container while trans-
porting it
Tipping the waste container while trans-
porting it can lead to injuries.
The vacuum material container can be lift-
ed by cranes at the handle. The maximum
load for crane transport is 50 kg.
Be aware of the permissible total weight of
the waste container when transporting it
with a crane and adhere to the applicable
legal regulations.
Inserting the dust bag
Insert the dust bag:
1. Apply the parking brake.
2. Unlock and lower the container.
3. Pull out the container by the handle.
4. Insert the dust bag. Take care to ensure
that the dust bag sits close to the con-
tainer wall and base.
5. Pull the edge of the dust collection bag
over the edge of the vacuum cleaner
waste container.
6. Fit and lock the container.
Removing the dust bag
1. Apply the parking brake.
2. Unlock and lower the container.
3. Switch on the device to avoid releasing
dangerous dusts.
4. Pull out the container by the handle.
5. Pull the dust bag upwards.
6. Seal the dust bag tightly with the closing
strip underneath the opening.
7. Dispose of the dust bag in accordance
with statutory regulations.
Closing the suction connection
WARNING
Danger of injury
Damage to the skin, lungs and eyes
through fine dust
The suction connection must be closed us-
ing the connection bushing after removing
the suction hose.
1 Fit the connection bushing exactly in the
suction connection and push all the way
in.
2 Turn the connection bushing all the way
to the right to close the suction connec-
tion.

Shutting down

Switching off the device
1. Switch off the device at the main switch.
2. Pull out the mains plug.