Table 5-2 Cable description (SUN2000-3.8KTL/5KTL/7.6KTL-USL0)
No.
Cable
1
Energy meter
signal cable
2
Emergency stop
switch signal
cable
Battery signal
3
cable
4
PV input power
cable
(Optional)
Ground cable at
the PV side
(GND)
5
Battery cable
6
Critical load AC
output power
cable
Issue 01 (2018-05-21)
Type
Multi-paired and individually foil
shielded cable that complies with
UL2919, CM/CMG (NEC type), or
CMH (CSA type)
PV cable that meets the 600 V
standard
Use cables that can withstand
90° C (194° F) or 105° C
(221° F).
Single-core outdoor copper
cable
Use cables that can withstand
90° C (194° F) or 105° C
(221° F).
Single-core outdoor copper
cable
PV cable that meets the 600 V
standard
Use cables that can withstand
90° C (194° F) or 105° C
(221° F).
Single-core outdoor copper
cable
Use cables that can withstand
90° C (194° F) or 105° C
(221° F).
Two single-core outdoor
copper cables (L1 and L2)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5 Electrical Connections
Conductor
Cross-sectional Area
Range
24–16 AWG
10–8 AWG
6 AWG
14–8 AWG
12–6 AWG
Source
Purchased by the
customer
Purchased by the
customer
Purchased by the
customer
Purchased by the
customer
Purchased by the
customer
Purchased by the
customer
Purchased by the
customer
38