1. Disconnect the generator and controller. Make the three output lines be short circuit to prevent
the blades from further running.
2. Do the reverse steps of installation to put down the generator.
○ Can I enlarge the batteries' capability to extend the available time for electrical appliance?
● Enlarge the capability of batteries we suggested would make the batteries on half full state
and short the life.
○ Wind turbine (3kw & above 3kw) can not trace wind direction automatically.
● 1. Check whether the anemoscope is broken or not. The concrete way is to examine whether
there is wind-speed indicator on controller;
2. Check whether the dogvane is broken or not. The concrete way is to unplug the plug of
dogvane from controller, and you will see there are three line on dogvane with marks ①、②、
③ . Measure the resistance between ① and ② by multi meter, the resistance should be
appropriately 1000 Ω , and then measure the resistance between ① and ③ , along with ②
and ③ . The resistance figure of these two( ① and ③ + ② and ③ ) should be equal to the
resistance figure between ① and ② .
3. If no problem exist the ahead two procedures, check whether the controller board has been set
on " auto " . Otherwise, it can not trace the wind direction automatically. If you can not trace the
wind direction, the reason causing this is mostly for low wind speed. Only when the wind speed
is larger than 3m/s staying more than 30seconds, can you trace wind speed and change
windward angle.