Settings
Display
Reset to factory
settings
Important information
For certain settings, the user code (359) is required.
* Some programs are protected by a code. If changes are necessary, the corresponding code
is provided.
5.6.2 Information
By pressing the Information key (81), you will reach the information
screen (the last selected information is displayed). The cursor keys
(79, 80) can be used to toggle between the possible information.
This screen can be left with the ESC key (71) or one of the program
keys (82, 83, ...).
Information
Display
Serial number
Software version
Furnace head
Firing hours
Furnace operating
hours
Latest start of the
calibration program
UTH
Latest start of the
calibration program
MTH
Calibration value UHT
Calibration value
MHT
Short Description
Information
With this setting
Mains voltage
option, all the values
and parameters can
be reset to the
original factory
Error list
settings.
Note: All the individ-
ual programs that
you have generated
and saved will be
deleted by this
function

5.7 Explanation of the display symbols

Symbol name
Open furnace head
Close furnace head
Press START
Short Description
Serial number of the
furnace
Press STOP
Press ENTER
Press ESC
Use cursor keys
Use – / + keys
Date of latest
calibration of the
temperature required
for crystallization.
General write
Date of latest
protection
calibration of the
temperature required
for sintering.
Calibration value at
Individual write
880°C/1616°F. The
protection active
value is displayed in
accordance with the
selected temperature
Individual write
mode in °C or °F.
protection not active
Calibration value at
1500°C/2732°F. The
value is displayed in
accordance with the
selected temperature
mode in °C or °F.
Display
Short Description
Shows the current
mains voltage
Enables the display of
the latest error
messages.
Meaning
Symbol
Shown in the
recommendation area,
where the next most likely
action is suggested.
Shown in the
recommendation area,
where the next most likely
action is suggested.
Shown in the
recommendation area,
where the next most likely
action is suggested.
Shown in the
recommendation area,
where a possible action is
suggested.
Shown in the
recommendation area,
where a possible action is
suggested.
Shown in the
recommendation area,
where a possible action is
suggested.
Shown in the
recommendation area,
where a possible action is
suggested.
Shown in the
recommendation area,
where a possible action is
suggested.
Shows in the parameter
list that the general write
protection for all programs
has been activated by
means of the user code.
Shows in the parameter
list that the individual
write protection for this
program is active.
Shows in the parameter
list that this program is
not write-protected.
21