4. Installation and Initial Start-Up

4.1 Unpacking and checking the contents

The packaging provides the following advantages:
– Reusable packaging
– Closing mechanism with integrated transportation grips
– Ideal protection by foam inserts
– Easy handling / optimum unpacking
– The packaging may be used in several ways (modules)
Remove the furnace components from their packaging and place the
furnace on a fire-proof table. Please observe the instructions on the
outer packaging.
There are no special transportation grips on the furnace. Support the
bottom of the furnace to carry it.
1
2
4
Check the delivery for completeness (see delivery form in Chapter 9)
and transportation damage. If parts are damaged or missing, contact
your local Ivoclar Vivadent Service Center. The packaging may be
disposed of with the regular household refuse.
Packing and shipping of individual components
The packaging of the CS4 permits simple and safe shipping of
individual components. Simply use the two corresponding inserts.
Fold the side flaps.
1
3
2
5
4
We recommend keeping the original packaging for future
service and transportation purposes.
1
3
2
5
4
3
5

4.2. Selecting the location

Place the furnace on a fire-proof, flat table using the rubber feet.
Make sure that the furnace is not placed in the immediate vicinity of
heaters or other sources of heat. Make sure that air may properly cir-
culate between the wall and the furnace and that there is enough
space for the swivel movement of the furnace head (at least 110
mm). Therefore, mounting the spacer (45) is absolutely mandatory.
Also ensure that there is enough space between the furnace and the
user, as the furnace releases heat during the opening of the furnace
head.
The Programat CS4 must not be used in the
immediate vicinity of patients.
The furnace should neither be placed nor operated
in areas where there is an explosion hazard. The
furnace must not be connected to the power supply
prior to or during the assembly.

4.3 Assembly

3
Make sure the voltage indicated on the rating plate (14) complies
with the local power supply. If this is not the case, the furnace must
not be connected.
5
Step 1:
Assembling the cooling tray (26)
Remove both screws (27) including the silicone washers (28).
27
28
14
27
28
13