Throttling Range; Setting Up The Outputs; Setting Up The Modulating Outputs - Honeywell T775A/B/M 2000 Series Installation Instructions Manual

Electronic stand-alone controllers
Table of Contents

Advertisement

SETUP
SENSORS
SENSOR B
Fig. 46. Setup - Sensors - Sensor B - Throttling Range.
SETUP
OUTPUTS
Fig. 47. Setup - Outputs Menu.
SETUP
OUTPUTS
MOD 1
Fig. 48. Setup - Outputs - Modulating Output Menu.
T775A/B/M SERIES 2000 ELECTRONIC STAND-ALONE CONTROLLERS
SETUP
SENSORS
SENSOR B
UNITS
CALIBRATE
SETUP
LABEL
SENSORS
LIMIT
SENSOR B
HI LIMIT
THROT RNG
THROT RNG
EXIT
ENTER
VALUE FOR
SENSOR B
THROTLING
RANGE
SETUP
OUTPUTS
MOD 1
MOD 2
# RELAYS
OPTIONS
RELAY 1
RELAY 2
RELAY 3
RELAY 4
EXIT
SETUP
OUTPUTS
MOD 1
TYPE
MIN OUT %
INTEGRAL
DERIVATIV
SCHEDULE
HIDE
EXIT

2.2.4.2. THROTTLING RANGE

only)
The throttling range for the modulating high or low limit
positions the setpoint at the end of the throttling range.
For example, with a high limit at Sensor B of 200°F and a
throttling range of 10°F, the modulating output controlling
Sensor A begins to throttle back at 190°F
(88°C), and fully closes at 200°F (93°C). Conversely, the
throttling range for the low limit begins above the setpoint
in the same manner.
10
o
F
1. From the Limit menu, use the
THROT RNG.
2. Use the
the desired value for the Throttling Range.
Default = 0
3. Press the
to the Limit menu.
M24510
4. Press the
5. Press the
return to the Setup menu.

2.3. Setting up the Outputs

1. From the Setup menu, use the
to highlight OUTPUTS.
2. Press the
NOTE: The menus (e.g. the Outputs menu shown
here) can display only those relays that are
defined in Setup (see "2.3.2. NBR OF
RELAYS" on page 24). For example, if you
configure only two relays, then only two
relays display on the appropriate menus.
M24511
The following procedures set up each modulating output
and relay output.

2.3.1. Setting up the Modulating Outputs

1. From the Output menu, use the
tons to highlight the desired modulating output
(MOD 1 or MOD 2).
2. Press the
menu.
NOTE: Modulating outputs are not available on the
T775A and T775B controller models. If you
are setting up one of these controllers, skip
to "2.3.2. NBR OF RELAYS" on page 24.
M24512A
Use the remaining procedures, beginning with "2.3.1.1.
TYPE (of output signal)" on page 22, to set up each
modulating output. If you have two modulating outputs,
repeat these procedures for each modulating output.
21
button to highlight
and
buttons to increase/decrease
button to accept the value and return
button to exit the Limit menu.
button to exit the Sensors menu and
and
button to display the Outputs menu.
button to display the selected MOD