Hardware Installation Manual
5.3
Connecting to E1/T1 Trunks
Depending on your model, the device connects to E1/T1 trunks using the following
connection type:
Telco connector for devices with 16 spans – see Section
RJ-48c connector for devices with 1, 2, 4, or 8 spans – see Section
5.3.1
Connecting 16-Span Device using Telco Connector
The procedure below describes how to connect the 16-span device. This connection uses
a 50-pin male Telco cable connector with pinouts as shown in the table below:
Table 5-1: E1/T1 Connector Pinouts for Each 50-Pin Telco Connector
1 to 8
1
2
3
4
5
6
7
8
The 50-pin male Telco cable mates with the device's female connector shown in the figure
below:
Version 6.4
E1/T1 Trunk Number
9 to 16
9
10
11
12
13
14
15
16
Figure 5-2: Device's 50-Pin Female Telco
Tx Pins (Tip/Ring)
27/2
29/4
31/6
33/8
35/10
37/12
39/14
41/16
21
5. Cabling the Device
5.3.1
on page
21
5.3.2
on page
Rx Pins (Tip/Ring)
26/1
28/3
30/5
32/7
34/9
36/11
38/13
40/15
October 2011
23