Corner setting 45° fixed socket
A. Distance to furniture (min.)
Distance to flammable materials (min.)
B. in front (floor)
C. to the side (floor)
D. to the rear (wall)
E. to the side of the wall

Installation distance in case of non-combustible wall

Using non insulated smoke pipe, the minimum distance to combustible wall must be
225 mm from smoke pipe.
We recommend a minimum distance to non-combustible material of 50 mm (F) for
cleaning considerations.
It should always be possible to access the access door.
RAIS - Manual for RAIS Q-Tee
Uninsulated flue
650 mm
300 mm
150 mm
225 mm
275 mm
Insulated flue
650 mm
300 mm
150 mm
175 mm
225 mm