*1
Connect peripheral options to terminals -, +1, +2, B1, and B2.
*2
For circuit protection, the main circuit is separated from the surface case that can touch the main circuit.
*3
The control circuit is a Safety Extra-Low Voltage circuit. Separate this circuit from other circuits with
reinforced insulation. Make sure that the Safety Extra-Low Voltage circuit is connected as specified.
*4
Reinforced insulation separates the output terminals from other circuits. Users can also connect circuits that
are not Safety Extra-Low Voltage circuits if the drive output is 250 Vac 1 A max. or 30 Vdc 1 A maximum.

Control Circuit Wire Gauges and Tightening Torques

Use shielded wire for control circuit terminal wiring. Use crimp ferrules on the wire ends for more reliable wiring.
TOMPYEUOQ2A03B AC Drive Q2A Installation and Operation Instructions
Figure 1.2 Standard Connection Diagram
1 English
EN
EN 9