The serial number uniquely describes the system and is used as identification in all further business processes. In the event of damage, immediately contact your nearest KSB service centre to maintain the right to claim under warranty. 1.2 Target group This operating manual is aimed at the target group of trained and qualified specialist technical personnel.
2 Safety 2 Safety All the information contained in this section refers to hazardous situations. DANGER 2.1 Key to safety symbols/markings Table 3: Definition of safety symbols/markings Symbol Description DANGER DANGER This signal word indicates a high-risk hazard which, if not avoided, will result in death or serious injury.
2 Safety 2.4 Personnel qualification and personnel training All personnel involved must be fully qualified to install, operate, maintain and inspect the equipment this manual refers to. The responsibilities, competence and supervision of all personnel involved in installation, operation, maintenance and inspection must be clearly defined by the operator.
1. On transfer of goods, check each packaging unit for damage. 2. In the event of in-transit damage, assess the exact damage, document it and notify KSB or the supplying dealer (as applicable) and the insurer about the damage in writing immediately.
3 Transport/Temporary Storage/Disposal 3.4 Disposal NOTE Due to certain components it contains, the device is classified as special waste and meets RoHs 2011/65/EC requirements. Once decommissioned, the device must be properly disposed of in accordance with local regulations. MSE/MSD 8 of 20...
Motor Protection relay Single-phase alternating current Three-phase current Max. amperage x 10 Code number 4.3 Name plate KSB SE & Co. KGaA Johann-Klein-Straße 9 67227 Frankenthal Deutschland MSD 60.1 LevelControl Basic 2 3/N/PE AC 400 V 50 Hz 1/N AC 230 V 50 Hz...
4 Description 4.5 Technical data Table 7: Electrical data Characteristic Value Rated operating voltage 1/N/PE AC 230 V / 50 Hz 3/N/PE AC 230 / 400 V / 50 Hz Setting range up to 1,2 A, 1,8 A, 2,6 A, 3,7 A, 5,5 A, 8,0 A, 11,5 A 0,16 A, 0,23 A, 0,36 A, 0,54 A, 1,2 A, 1,8 A, 2,6 A, 3,7 A, 5,5 A, 8,0 A, 11,5 A Rated insulation voltage...
5 Installation at Site 5 Installation at Site 5.1 Safety regulations DANGER Incorrect installation Danger to life! ▷ The control unit must be installed in a flood-proof location. ▷ Never install the control unit in potentially explosive atmospheres. ▷ The control unit is not suitable for controlling pumps in potentially explosive atmospheres.
Page 12
5 Installation at Site CAUTION Improper electrical connection Damage to the control unit/control cabinet! ▷ Check the type of current and voltage of the mains. ▷ Observe the wiring diagrams. ü The mains voltage matches the rated voltage specified on the name plate. 1.
6 Commissioning/Start-up/Shutdown 6 Commissioning/Start-up/Shutdown 6.1 Prerequisites for commissioning/start-up Before commissioning/starting up the pump set, make sure that the following conditions are met: ▪ All relevant VDE standards and/or regulations applicable in the country of use are complied with. ▪ The pump cable has been connected. ▪...
6 Commissioning/Start-up/Shutdown The fluid handled is pumped off until the stop level of the float switch is reached. When the switch is set to “manual” mode, the pump can be started up directly. However, this should be done only above the stop level and for short periods, e.g., for checking the direction of rotation.
Pump will re-start after cooling down. breaker. (If unit is repeatedly tripped by thermal circuit breaker, both pump and motor have to be checked mechanically and electrically by KSB’s customer service.) ✘ - Wrong setting of motor protection relay Set to rated motor current.
10 EU Declaration of Conformity 10 EU Declaration of Conformity KSB SE & Co. KGaA Manufacturer: Johann-Klein-Straße 9 67227 Frankenthal (Germany) The manufacturer herewith declares that the product: MSE, MSD Series code range: 2018w01 to 2019w52 ▪ is in conformity with the provisions of the following Directives as amended from time to time: –...
Index Index Commissioning/start-up 13 Design 9 Disposal 8 Faults Causes and remedies 16 Name plate 9 Other applicable documents 4 Safety 5 Safety awareness 6 Storage 7 Transport 7 MSE/MSD 19 of 20...