I-Installing The Stainless Steel Top; Operation; A-Prestart Checks; B-Temperature Control - Traulsen UHT Series Owner's Manual

Hide thumbs Also See for UHT Series:
Table of Contents

Advertisement

III. INSTALLATION (continued)
III. i - INSTALLING THE STAINLESS STEEL TOP-UHT:
All 27", 32, 48, and 60" wide compact undercounter models can be
supplied with an optional stainless steel top. This must be installed
on-site, to do so please follow the directions below.
1. Peel Off backing and install foam tape (provided) around entire
perimeter of the top of the unit.
2. A flange is assembled underneath at the front of the counter top.
This flange has two screw holes. Screw the two 1/4-20x5/8" screws
(provided through the holes in this front flange into the threaded holes
in the front of the top edge of the unit.
3. Using the five 10-16x1/2" screws provided, screw the bottom of the
rear cover plate to the upper rear of the cabinet.
4. If the optional polyethylene cutting board top is provided, there are
four threaded pins which screw into the four threaded holes in the work
top. The four holes in the polyethylene cutting board top fit around the
heads of the four pins.
IV. OPERATION
IV. a - PRESTART CHECKS:
The compressor must float freely before connecting to electrical power.
The compressor motor is provided with rubber vibration isolator mounts
(no springs). No bolts need to be loosened. Check all exposed refrigera-
tion lines to make sure they are not dented or kinked. Check for tubing
shifts due to shipping that would cause operating noise, wear, or leaks.
Check that condenser fan rotates freely.
The refrigeration system should be checked for proper operation before
product is stored in the cabinet.
IV. OPERATION (continued)
IV. b - TEMPERATURE CONTROL:
The temperature is set at the factory but local conditions may necessitate slight
adjustment.
The temperature control shown in below is located on the front side of the evapo-
rator housing. To adjust, turn the adjustment screw with a screwdriver a small
amount at a time; turning clockwise lowers the temperature. An "OFF" position
is fully counterclockwise and interrupts power to the compressor and condenser
fan only, not the entire refrigerator.
ULT32 freezer model is equipped with a knob that has a number ranging from 0
to 9. Turning the knob clockwise lowers the temperature, turning the knob coun-
terclockwise raises the temperature. O is the "OFF" position. The temperature
range of adjustments is -5 to 5 F degrees.
IV. c - DEFROST CONTROL:
Frozen food storage cabinets are equipped with a defrost timer that provides a 20
minute defrost cycle every 6 hours (four defrost cycles per day).