HEAT INTERFACE UNIT COMMISSIONING CHECKLIST (cont'd)
DWELLING SYSTEM
Heat emitters type:
Controls section:
Time and temperature control to heating:
Time and temperature control to Hot Water:
Hot Water Zone Valves: (Stored)
Thermostatic radiator valves:
Automatic Bypass to System:
Design Detail:
Pump setting: (if applicable)
Auto bypass setting: (if adjustable)
Radiator circuit:
If 'Manifold' where is it:
Number of heating zones:
Cold fi ll pressure: (bar) (heating circuit)
Expansion vessel pre charge pressure valve: bar (g)
Filling loop disconnected and capped:
Safety valve setting: bar (g)
Discharge pipework has been connected:
Separate air vent's: (external to unit)
If 'yes', location:
Secondary Strainer fi tted:
Cold water meter installed?
Drain cocks fi tted:
DOMESTIC HOT WATER MODE
Type:
Store Details: (If present)
Make and model:
Serial number:
Date commissioned:
Appropriate Benchmark Commissioning Checklist completed for cylinder: (if not instantaneous)
Instantaneous systems only: (types 1,2,3)
What is the incoming static cold water pressure at the inlet to the system? bar (g)
Has a strainer been cleared of installation debris (if fi tted)?
Is the installation in a hard water area (above 200ppm)?
If yes, has a scale reducer been fi tted?
What type of scale reducer has been fi tted?
What is the hot water temperature set to?
DHW recirculation fi tted?
HEAT METERS
Heat Meter commissioned?
Error Codes cleared?
ALL INSTALLATIONS
The HIU system complies with the appropriate Building and Trading Regulations?
The system has been installed in accordance with the manufacturer's instructions?
If an external cylinder has been connected, compatibility with HIU has been checked?
The manufacturer's literature, including the Benchmark Checklist and Service Record, has been completed clearly and left with the HIU?
Commissioning Engineer's Signature
Commissioning Engineer's Name and Company: (Printed)
Date:
(To confi rm satisfactory demonstration and receipt of manufacturer's literature)
* All installations in England and Wales must be notifi ed to Local Authority Building Control (LABC) either directly or through a
Competent Persons Scheme. A Building Regulations Compliance Certifi cate will then be issued to the customer.
© Heating and Hotwater Industry Council (HHIC)
Radiators
Underfl oor system
Room thermostat and Programmer/Timer
Cylinder thermostat
Fitted
Fitted
Fitted within HIU
Inside unit
Instantaneous
Vented Store
MVHR
Programmable Room Thermostat
Load/Weather Compensation
HIU
Radial
Yes
Yes
(In accordance with the relevant regulations)
Yes
Outside unit
Unvented Store
Yes
Yes
Yes
Yes
www.centralheating.co.uk
Fan Coil
Not applicable
Not applicable
Not applicable
Fitted outside HIU
Manifold
Not applicable
Not applicable
Yes
None
Yes
Thermal Store
Yes
Not applicable
No
Yes
No
No
Yes
Yes
Yes
Yes
Yes
53