DIAGNOSTIC TOOL (next)
• The following window opens. Click "Finish".
• The installation is complete.
B - Connect the cable and its "MUXDIAG II" interface to a USB port on your computer
• Connect the cord to the motorcycle's diagnostic connector.
• Ensure that there are no problems with the feed to the "MUXDIAG II" box by checking the
LEDs :
Blue fixed : connection with PC correctly established.
- Blue flashing : communication with PC in progress.
- Blue off : connection lost to the PC, peripheral device off or in standby, may also indicate a
problem with the USB.
- Green fixed : problem with embedded software.
- Green flashing (slow) : embedded software running correctly.
- Green flashing (fast) : communication with PC in progress.
- Green off : no embedded software.
- Red fixed : card correctly powered.
- All LEDs off : the connector is not powered, has been deactivated or is in USB standby.