3g and lte based modem.
Table of Contents

Advertisement

Smart SAM4Q User Guide V1.1
REMOTEIP2:
REMOTEIP3:
REMOTEIP4:
SMSBLOCK: 1
REMOTESMS1: 0413586218
REMOTESMS2:
REMOTESMS3:
REMOTESMS4:
DIALBLOCK: 1
REMOTEDIAL1: 0395612959
REMOTEDIAL2:
REMOTEDIAL3:
REMOTEDIAL4:
OK
AT$LGSMS
Use to program parameters for last gasp SMS.
Parameters are defined as:
LGSMSMSG=SMS message text, default is "SAM4Q low power detected..."
Time delay to make sure supply power is down for this long before sending last gasp
LGSMSDELAY=
SMS
LGSMSNO=SMS phone number
AT$LGSMS= LGSMSMSG= SAM4Q power supply is low....,60,LGSMSNO=+61418505361
Saved parameters to flash...
OK
AT$LGSMS?
$LGSMS:
LGSMSMSG: SAM4Q power supply is low....
LGSMSDELAY: 60
LGSMSNO: +61418505361
OK
AT$LOGIN
Use to setup login details for remote sending of AT commands, parameters and software updating; password
is encrypted so remote login required PC software Smart SAM4Q Terminal.