Configuration And Diagnosis Via The Web Interface - WEISS WSG 32 Mounting And Operating Manual

Electrical compact gripper
Table of Contents

Advertisement

Hysteresis is used to prevent the states chattering to and fro. If there is a voltage error, the power output
stage will be switched off using a Fast Stop and a voltage error will be indicated. Acknowledging the
FastStop is possible only if the operating voltage is back in its allowed range. Acknowledging can be done
either via the web interface or via the command interface by using the "Fast Stop Acknowledge" command.
Loss of gripper force following an error due to the voltage being too high or too low!
The low voltage fault will also be triggered if the power supply is interrupted when switching the
force off, e.g. via an emergency stop relay.
This error can only be acknowledged if there is no longer a high/low voltage error.
For the documentation of the system status word and the command to acknowledge the "Fast
Stop" via the command interface, see the "WSG Command Set Reference Manual".

9.14 Configuration and diagnosis via the web interface

The module has an integrated web server, with a user interface for configuration and diagnosis. To use this,
the module must be connected via Ethernet. To get to the configuration user interface, open a browser and
enter the module's IP address (on delivery this is 192.168.1.20) into the browser's address line:
The following browsers have been tested and support the module's web interface:
Mozilla Firefox 16 and above
Google Chrome 23 and above
Apple Safari 5 and above
Mobile Safari (iOS 4.3 and above)
Internet Explorer 8 and above
To display the web user interface, JavaScript must be enabled in your browser.
will show the error state.
Figure 26: Entering the IP address to start web-based configuration
- 41 -

Advertisement

Table of Contents
loading

Related Products for WEISS WSG 32

Table of Contents