REPLACING THE VOLUME
1
Turn the power off.
2
Take out the 2 screws and remove the
Potentiocover (FIG. 11. 1 c).
3
Disconnect the connector of the
Volume to be replaced.
4
Remove the screw which secures the
Potentiobase (FIG. 11. 1 b).
Remove the Potentiobase together
5
with the Volume as is attached.
(FIG. 11. 1 c)
6
Remove the Base and Gear to replace
the Volume.
7
Adjust the Volume as per the previous
page after replacing.
11 - 2 GREASING
Be sure to use the designated grease. Using undesignated grease can cause parts
STOP
damage.
IMPORTANT!
Once every 3 months, apply greasing
to the Spring and Gear mesh portion.
For spray greasing, use GREASE
MATE (PART No. 090-0066).
www.seuservice.com
TRUSS SCREW (2)
M4 X 8
FIG. 11. 1 c
GREASING
40
POTENTIOCOVER
POTENTIOBASE
FIG. 11. 2