Maintenance overview

Maintenance location
After 10 operating hours
Retighten all screw and plug-in
connections as well as the hydraulic
connections.
Retighten allwheel nuts
M18 x 1.5 - 300 Nm
M22 x 1.5 - 510 Nm
Before the season
Complete machine
In use
Hydraulics
WARNING
Hydraulic system and components
Hydraulic hoses
Pressure accumulator
Pronto 8 SW / 9 SW
Work instructions
Even firmly tightened screw connections can come loose (e.g.
because of material settlement or paint residues between the
screw elements). This can lead to loose screw connections
and leaking hydraulic connections.
¾ initially after 10 hours or 50 km
¾ again after 10 hours or 50 km
¾ then retighten daily until the screws have settled and further tightening
is no longer possible.
¾ then always before the start of the season and every 50 operating
hours during use.
Read the operating instructions carefully as a refresher.
Check all screw connections for firm seating and retighten
as necessary
Check condition and function of all protective features and
replace, if necessary
Check electrical lines for damage and replace, if necessary.
Lower all hydraulically lifted parts (e.g. wings, packer, undercarriage,
etc.) to the ground before performing any work on the hydraulic system.
Depressurise the hydraulics on the tractor and implement side!
Allow hydraulic oil heated during operation to cool down before any work
on the hydraulic system.
Observe the notes on hydraulics in the chapter Safety and responsibility.
Check all hydraulic components and hoses for function,
leak tightness, fastening and chafing
Check the hydraulic hoses regularly for damage (cracks, chafing, etc.).
Replace damaged and faulty hoses immediately.
Hydraulic hoses must be replaced after 6 years. Pay attention to the
manufacturing date on the crimp sleeve (year/month) and the hose
(quarter/year):
Crimp sleeve
Depending on the conditions of use (e.g. weather influences) or in case of
higher strains on the machine the hoses may need to be replaced earlier.
Have the hydraulic system checked by an expert at least once every
year.
In addition follow the country specific regulations and directives.
Follow the country-specific regulations and directives.
Hose
Interval
Once
40 h
59