Enter the following at each keypad installed on the
system:
1. Enter Installer Programming by pressing
[*][8][Installer's Code]
2. Press [000] for Keypad Programming
3. Press [0] for Partition and Slot Assignment
4. Enter a two digit number to specify the partition
and slot assignment.
NOTE: If your system does not have partitions,
enter [1] for the first digit.
1st digit
Enter 0 for Global Keypad
Enter 1 for Partition 1 Keypad
Enter 2 for Partition 2 Keypad
2nd digit
Enter 1 to 8 for Slot Assignment
5. Press the [#] key twice to exit programming.
6. After assigning all keypads, perform a supervisory
reset by entering [*][8][Installer's Code][902]. The
panel will now supervise all assigned keypads
and enrolled modules on the system.
To review which modules the control
panel is currently supervising:
1. Enter [ ][8][Installer's Code]
2. Enter [903] to display all modules. On the
N
S
T
A
L
L
A
T
LCD5501Z32-900 keypad, 1 1 1 1 1 and 1 1 1 1 1 7 7 7 7 7 will scroll on
the keypad to indicate that the LCD5501Z32-900 is
present on the system. 1 1 1 1 1 designates the keypad
section, and 17
section is also supervised. On the LCD5500Z
keypad, scroll until the module name appears on
the display.
3. To exit press [#].
If both modules do not show on the keypad, one of
the following conditions may be present:
• the keypad is not connected properly to the Keybus
• there is a problem with the Keybus wiring run
• the keypad does not have enough power
3
I
O
N
17
17
17 is used to show the receiver
17