Enrolling & Programming Handheld Keypads - DSC LCD5501Z32-900 Installation Manual

Table of Contents

Advertisement

E N R O L L
Opening/Closing By Wireless Key
Reporting
NOTES: The Identified Wireless Key Closing option is
only available with the PC5010 v2.0, PC5008 v2.0 and
higher by turning section [015] option 4 off.
The Identified Wireless Key Opening option is only
available with the PC1555 v2.1, PC580 v2.1, PC5008
v2.1 and higher, PC5015 v2.2 and higher by turning
section [017] option 1 off.
To enable the reporting of closings by identified
wireless keys:
• Make sure the control panel is v2.0 or higher
• Program a valid access code for each key
• Program a closing reporting code for each key's
access code
• Disable the Quick Arm option in section [015]
option [4]
To enable the reporting of openings by identified
wireless keys:
• Make sure the control panel is v2.1 or higher
• Program a valid access code for each key
• Program an opening reporting code for each key's
access code
• Enable the WLS Key Uses Access Codes by
turning section [017] option [1] off.
Command Output Activation
NOTE: The Identified Wireless Key Command Output
Activation feature is only available with the PC5010,
PC5015, PC5008, PC1555 and PC580 v2.0 and
higher.
To enable command output activation by wireless
keys, ensure that:
• Make sure the control panel is v2.0 or higher
• Program a valid access code for each key
• Enable the PGM output attribute Requires Access
Code for each PGM output programmed as
[ ][7][1-4] in sections [141] to [154].
&
P R O G R A M
3.5 Enrolling & Programming
Handheld Keypads (WLS910)
For handheld keypads to work on the system, you
need to enroll them and then program the function
buttons. You can enroll up to 4 handheld keypads on
the system.
Enroll Handheld Keypads
1. At a system keypad, enter [ ][8][Installer's code]
to go to the Installer's Programming section.
2. Enter programming section [804].
3. Enter a 2-digit number (33-36) to assign the
handheld keypad a slot. These numbers
correspond to handheld keypad numbers 1-4.
4. Enter the keypad's ESN. The entry must be six
digits. If an older keypad with a 5-digit ESN is
being enrolled, add the digit [0] to the beginning
of the ESN. (E.g. ESN=21234, enter 021234)
5. The keypad is now enrolled on the system. Record
the serial number and the assigned slot number
in the programming worksheets in the back of this
manual.
6. Repeat steps 3 - 5 until all handheld keypads have
been enrolled.
7. (PC5010 and PC5015 only) By default, all
handheld keypads are assigned to Partition 1. To
assign a keypad to Partition 2, enable the
appropriate options in programming section [90].
NOTE: A handheld keypad can only be assigned to
one partition.
8. To exit press [#].
Program the WLS910 Function Buttons
WLS910 handheld keypads have four programmable
function buttons. You must program a set of four
functions for the function buttons to work.
For systems not using partitions: program the
function buttons in section [57]. All handheld keypad
buttons will have the same four functions.
9