YASKAWA VS-505WII Manual page 18

Industrial use thyristor converter units. type cdmr-w11 s, l, m
Table of Contents

Advertisement

(REFERENCE)
(Cont'd)
FUNCTIONS OF EXTERNAL CONTROL TERMINALS
1 8
Table 11 Functions of External Control Terminals for Input
Notes
1.
Use highly reliable contact for input interface signal considering that the load is 48 VDC, 10 mA .
2. Provide a noise killer at both ends of coil when relays, contactors, etc. are used .
Signal Name
Terminal
Function
1
Ready signal
-
0-
30
"Close" --- Field intensifying .
"O "men" --- Gate block + Field half-reduced .
2
Operation signal
29
"Close" --- Speed reference "ON" -; Acceleration to speed
--0
reference value .
"Open" --- Speed reference "OFF" - Stop by regenerative
braking + Gate block .
29
"RUN" --- Speed reference "ON" -} Acceleration to spee,"
reference value .
j j
28
"STOP" --- Speed reference "OFF" -" Stop by regenerative
~
braking - Gate block .
3
Quick
stop
27
Quick stop at ' Close' in case of soft start operation .
signal
-o
o-
"Close" --- Speed reference "OFF" -} Stop by regenerative
braking
-r
Gate block .
4
Main circuit M
2
"Close" --- Gate block
Terminals 26 and 35 (or 36)
input answer back
~ 0-
released .
short-circuited unless used .
signal
5
Motor overheat
33
"Open" --- Gate block .
si nal
-
-
"Close" --- Normally .
"
Field block signal
3
"Close" --- Fie143 block . (Field circuit clipped at
PP
-° °-
phase .)
7
Motor blower
31
"Close" --- Field intensifying .
ON /OFF signal
°-
"Open" --- Gate block -~ Field current half-reduced .
8
External gate
_
4 - 47
"Close" --- Gate block .
block signal
9
External (OCL)
45 - 46
"Close" --- Normally.
Terminals 45 and 4 " short-
failure reset
~~-
"Open" --- Reset .
circuited when reset button in
the unit is used .
10
Fuse blown
R1 - R2
"Open" --- Normally .
detection signal
"Close" --- Gate block .
(inside)
11
Thyristor cooling
R3 - R4
With failure detection cooling fan (option) .
fan stop signal
__0
"Open" --- Normally .
(inside)
"Close" --- Gate block 
12
Speed reference
t& V /100$N
" Soft start commnw" -"zei~~z : e.
(
0+
Forward,
(D
7
-4 V '100
""
" 3 to 75
(Variable)
Reverse)
8
±10 V /100%N
sec .
9
f15 7100%N Accel . time, decel. time ad-
10
0 V (SG)
justable independently .
12
*6 V / 100$N
Terminals 11 an,. 1 short-
circuited.
13
± 6 V/1000
/6
N
13
External current
reference (
(D
14
±3 V/100% Ia
Forward torque,
0
Reverse
15
0 V (SG)
torque)
14
Speed feedback
-
DCTG 2
3 (+)
signal
15
CEMF compensation
48
Forward : 4 V/1U0% Va
Reverse:
+6 V/100% Va
1 "
Automatic field
1
Output received from field controller Type JGSM-51 .
weakening current
command
17
Speed feedback
5
" Output from Type JGSM- 5
(Voltage feedback)
When reversible operation by ACTG . (OPN :
Open)
" Output from type JGSM-53
When speed controlled by voltage detection .
(OPN :
OP , en)