Figure 4-13
TM31 object
Table 4- 9
List of signals for the operation screen – TM31 object
Signal
Analog input 0 [V, mA]
Analog input 1 [V, mA]
Analog input 0, scaled
analog input 1, scaled
Cabinet Modules Operator Panel AOP30
Operating Instructions, 04/2014, A5E03263551A
Operation screen - example of a drive with vector control
Parameter
r4052[0]
r4052[1]
r4055[0]
r4055[1]
4.6 Menu commissioning / service
Short name
Unit
AI_UI
V, mA
AI_UI
V, mA
AI_%
%
AI_%
%
Control via the operator panel
Normalization
(100% = ...)
V: 100 V / mA: 100 mA
V: 100 V / mA: 100 mA
as set in p200x
as set in p200x
51