Pebble Arrangement; Test For Spillage - Focus MEIJIFOCUS Installation, Servicing And User Instructions Manual

Hide thumbs Also See for MEIJIFOCUS:
Table of Contents

Advertisement

User instructions
Next place the Split small log leaning on the larger log, as shown in the
photo below.
Next place the three small logs around the larger log, as shown in the
photo below.
Next place the Medium log on the left around the larger log, as shown in
the photo below.
Finally open the bag of Embers and scatter it over the top of the burner
between the logs.
B. PEBBLE ARRANGEMENT
Parts – 22 ceramic pebbles.
Place the Ceramic Mat on the Burner Top, aligning the holes with those
on top of the burner. Place 5 pebbles along the rear of the burner (1 to
5). Place another row of 5 pebbles in front of these (6 to 10). Now place
3 pebbles in front of the centre (11 to 13), 3 pebbles of the previous row.
Next, place 3 pebbles to the R/H side of the Pilot shield and forward of the
previous 3 pebbles (14 to 16). Place 1 pebble in both of the front corners of
the burner (17 to 18). The remaining 4 pebbles are nested on top of the 2nd
and 3rd row of pebbles (19 to 22). This can all be seen in the figure below.

TEST FOR SPILLAGE

IMPORTANT
A spillage test MUST be made before the installed Fire is left with the
customer.
Carry out the test by first closing all doors and windows in the room
containing the Fire.
Ensure that the Fire is burning at full rate for a minimum of 5 minutes.
With the appliance still lit apply a smoke match or smoke puffer into the
flue or gas fire canopy, and ensure that all smoke is drawn into the flue.
If there is a fan in a nearby room the spillage test must be repeated with the
fan running and all connecting doors between the fire and fan left open.
If there are still problems the chimney/flue may require attention.
Disconnect the Fire and seek expert advice.
06

Advertisement

Table of Contents
loading

Table of Contents