User instructions

FLUE CONNECTION

Before installation of the appliance the chimney or flue must be inspected
by a competent person and passed as suitable. A smoke test should be
carried out before the installation of the Fire.
This appliance is suitable for Class 1 flues (the Building Regulations 1984).
It is the responsibility of the installer to ensure that the flue suitable for the
conditions experienced when burning gas.
The minimum effective height of the flue must be 5 metres measured
from the hearth to the Terminal of the flue. If the flue has any non-vertical
sections the height should be increased. Prior to installation the installer
should ensure that the flue is free from obstruction and ideally a chimney
should be swept and subsequently smoke tested. Ensure that any
dampers are fixed in a permanently open position.

CONNECTING THE GAS SUPPLY

Ensure that the gas supply pipework is capable of delivering the required
volume of gas in accordance with the relevant Standards.
A gas soundness test must be carried out before operating the Fire.

PRESSURE TESTING

The gas pressure to the burner must be measured at the burner test nipple.
Burner Pressures required are given in the table in section 2 Technical
Information of this manual. A tolerance of +/-5% may be applied to these
burner pressures.

ARRANGING THE LAYOUT OF THE COALS

Only the ceramics supplied with this appliance are to be used. The logs
should only be laid as shown on the following pages. Replacements are
available from your dealer, but should be installed by a competent person.
IMPORTANT
Please ensure that when fitting the ceramics, that you do not obstruct
the pilot.
Focus accept no responsibility for any injury sustained whilst handling
hot ceramics.
A. LOG ARRANGEMENT
Parts – 6 ceramic logs, 1 bag of embers.
Lay the logs as shown in the diagrams below.
Start by placing the Large log in the centre of the Burner Top. Locating the
log centrally and symmetrical with the holes in the Top Plate.