Electrical Connections
_k
WARNING
To maintain proper tool grounding,
whenever outlet you are planning to
use for this power tool is of 2-prong
type do not remove or alter ground-
ing prong in any manner.
An adapter
is available
for connecting
the
plug to 2-prong
receptables.
The green
grounding
lead extending
from the adapt-
er must be connected
to a permanent
ground
such as to a properly
grounded
outlet box.
Grounding
Lug
3-Prong
/
_
Make
Sure
This
Is
Plug
_W7
/
1_
Gonnec_d
To A,
\
a2T ll
Koown rou°o
2-Prong
Adapter
Receptacle
,_
WARNING
Adapter
illustrated
is for use only if
you
already
have
a properly
grounded
2-prong
receptacle.
Extension
Cords
The use of any extension
cord will cause
some loss of power.
Determine
the mini-
mum wire size (American
Wire Gage No.
(AWG#))
extension
cord. Use only 3-
wire extension
cords with 3-prong
ground-
ing type plug and 3-pole receptacles
which
accept the tool's plug.
Motor Protection
& Reset
Button
The motor protector
opens the power line
circuit and stops the motor when the
motor temperature
exceeds
a safe level,
the motor is overloaded,
or a low voltage
condition
exists.
When the protector
activates,
immedi-
ately turn saw off, remove
yellow key and
wait for motor
to cool. Push red re-set but-
ton and listen/feel
for click to indicate
protector
is re-set. If you do not hear/feel
a click, motor is still too hot. Wait a while
longer and repeat.
Wire Sizes Required (AWG #)
Cord
Length
120V
240V
0-25 ft
No. 14
No. 16
26-50 ft
No. 12
No. 14
51-100 ft
No. 10
No. 12
Note:
The smafler the gauge number,
ttre heavier
the cord. For circuits farther
away from the electrical
circuit box, wire size must
be h_creased propor-
tionately
to deliver ample
voltage to the motor.