TROUBLESHOOTING

PROBLEM
Jack will not lift
Jack lifts only
partially
Jack advances slowly
Jack lifts load, but
doesn't hold
Jack leaks oil
Jack will not retract
Jack retracts slowly
POSSIBLE CAUSE
Release valve in wrong
position.
Low/no oil in reservoir.
Air-locked system.
Load is above capacity of
jack.
Delivery valve and/or bypass
valve not working correctly.
Seals worn out or defective.
Too much or not enough oil
Pump not working correctly
Leaking seals
Cylinder packing is leaking
Valve not working correctly
(suction, delivery, release or
bypass).
Air-locked system
Worn or damaged seals
Release valve control in wrong
position
Cylinder damaged internally
Made in China to TQB Brands Pty Ltd specifications
Visit us at www.tqbbrands.com.au
Product Code: BPROAJ22T
ACTION
Move release valve to UP
position.
Fill with oil and bleed
system.
Bleed system.
Use correct equipment.
Clean to remove dirt or
foreign matter. Replace oil.
Install appropriate seal kit.
Check oil level
Install seal kit, or replace
power unit
Install seal kit
Install seal kit
Inspect valves. Clean and
repair seat surfaces
Bleed system as per
instructions
Install seal kit
Move Release valve to
DOWN position
Send jack to authorised
service centre