DIAGNOSTICS menu
Figure 89
DIAGNOSTICS menu details (continued) (see Figure 87, page 76 for access information)
Menu/Item
Units
TO RESET ALL HISTORY
AND COUNTERS TO ZERO:
Status
text
Temperatures
menu
Inputs
menu
Outputs
menu
Lockout History 3
Fault Name
text
Fault Type
text
Time
text
Date
text
Status
text
Temperatures
menu
Inputs
menu
Outputs
menu
Software Versions
Display
E#.##
Main Micro
E#.##
Second Micro
E#.##
Manual Test Mode
Status
text
Inputs
text
Target
°F
Boiler Out
°F
Boiler In
°F
Flue
°F
Outdoor
°F
Blower Speed
rpm
Flame Signal
no units
Force Rate
Manual Reset

DATE AND TIME menu

Figure 90
DATE AND TIME menus — navigation (see Figure 78, page 70 for access information)
Set Time and Date
Year
text
Month
text
Day
text
Hour
text
Minute
text
78
2
-
G
AS
FIRED WATER BOILER
(continued)
Low
High
Default
Value
Value
To reset all history and counters to zero: Enter the DIAGNOSTICS menu. Then press and hold
the left and right arrows located below the display. Hold for 3 seconds. This will cause ALL history
and counters to be deleted.
Data
menu
menu
menu
Data
Data
Data
Data
Data
menu
menu
menu
Data
Data
Data
Data
HEAT or DHW
Data
Data
Data
Data
Data
Data
Data
Data
Low, Med, High, or Auto
Auto
2013
1
1
12 (AM)
0
— Boiler Manual
Comment
Displays the boiler's status when the error occurred
Choose this to view the Boiler Temperatures at the time of the error
Choose this to view the status of the Boiler Inputs at the time of the error
Choose this to view the status of the Boiler Outputs at the time of the error
Choose this to view the most recent error recorded
Displays the name of the fault
Displays whether the fault was MANUAL OR AUTO reset
Displays the time error occurred
Displays the date error occurred
Displays the boiler's status when the error occurred
Choose this to view the Boiler Temperatures at the time of the error
Choose this to view the status of the Boiler Inputs at the time of the error
Choose this to view the status of the Boiler Outputs at the time of the error
Software version of the microprocessor on the display circuit board
Software version of the main microprocessor on the control circuit board
Software version of the second microprocessor on the control circuit board
Current operating status of the boiler: Prepurge, Ignition, Heating or DHW, Post Purge, Warm
Weather Shutdown (WWSD), Fault
Indicates status of calls for heat on Heating and DHW inputs
Calculated target temperature based on outdoor temp (for Heating input) or the DHW Boiler
Supply temperature (for DHW input)
Temperature of the outlet sensor on the boiler heat exchanger
Temperature of the inlet sensor on the boiler heat exchanger
Temperature of flue gases
Temperature of outdoor air
Blower's feedback to the control
Number indicating the presence and quality of the flame used to prove flame presence and
shut down boiler
Used to manually force a rate during a call for heat. Choose auto for normal operation.
Reset selected condition
Set year (homeowner or contractor)
Set month (homeowner or contractor)
Set day (homeowner or contractor)
Set hour (homeowner or contractor)
Set minute (homeowner or contractor)
Part number 550-142-190/1218