SECTION 4
4.3

SERVICE AIR PIPING

Before installing the compressor, review the service
air system's layout including: pipe sizes, auxiliary
separator tube, drip legs, line filter(s), and isolation
valves (See Figure 4-3).
NOTE
Systems using both reciprocating and
rotary screw compressors must isolate
the two types from each other through the
use of a common receiver tank. Air lines
from each individual compressor should
be connected directly to the common
receiver tank.
Figure 4-2: ST1100, ST1500 Shipping Studs
1. Belt Guard
2. Nut (2)
02250180-090 R00
S
HOP
3. Shipping Studs (2)
P
S
IPE
IZING
Pipes should be sized as a minimum to match the
dimensions
of
the
connection. All piping and fittings should be rated for
the discharge pressure.
A
R
UXILIARY
ECEIVER
An auxiliary receiver tank should be installed in
systems where large demand fluctuations will occur.