SECTION 6
Figure 6-11: Belt Tension Adjustment, ST1100, ST1500, 15-20HP
1. Belt Guard
2. Belt Tension Adjustment Screw
3. Locking Nut
4. Jacking Nut
6.9
REPLACEMENT AND
ALIGNMENT OF BELT
PULLEYS
In the event of the motor or compressor unit having
been removed and replaced, pulley alignment will
have to be checked and adjusted.
Misalignment of pulleys can cause rapid wear of the
V belt form, considerably shortening the service life
of both belts and pulleys. Due to Sullair's innovative
design, only parallel alignment of the drive pulleys
needs to be checked
5. Comp. Unit Mounting Plate Bolts (4)
6. Comp. Unit Pulley
7. Belts
8. Motor Pulley
P
ARALLEL ALIGNMENT CAN BE CHECKED BY TWO
.
METHODS
1. Placing a straight edge against the pulleys
near their centers.
the straight edge must be sitting flat against
both pulleys, i.e. full face contact. There
should be no more than 0.5mm misalign-
ment.
2. Using a laser, ensure misalignment is no
greater than 0.5°.
02250180-090 R00
USER MANUAL
S
T
HOP
EK
For correct alignment,
65